Parallelization of Garfield++ and neBEM to simulate space charge effects in RPCs

Abstract

Numerical simulation of avalanches, saturated avalanches, and streamers can help us understand the detector physics of Resistive Plate Chambers (RPC). 3D Monte Carlo simulation of an avalanche inside an RPC, the transition from avalanche to saturated avalanche to streamer may help the search for the optimum voltage and alternate gas mixtures. This task is dauntingly resource-hungry, especially when space charge effects become important, which often coincides with important regimes of operation of these devices. By modifying the electric field inside the RPC dynamically, the space charge plays a crucial role in determining the response of the detector. In this work, a numerical model has been proposed to calculate the dynamic space-charge field inside an RPC and the same has been implemented in the Garfield++ framework. By modeling space charge as the large number of line charges and using the multithreading technique OpenMP to calculate electric field, drift line, electron gain, and space charge field, it has been possible to maintain time consumption within reasonable limits. For this purpose, a new class, pAvalancheMC has been introduced in Garfield++. The calculations have been successfully verified with those from existing solvers and an example is provided to show the performance of pAvalancheMC. Moreover, the details of the transition of an avalanche into a saturated avalanche have been discussed. The induced charge distribution is calculated for a timing RPC and results are verified with the experiment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tanay Dey, Purba Bhattacharya, Supratik Mukhopadhyay, Nayana Majumdar, Abhishek Seal, Subhasis Chattopadhyay. 2023-10-05. Parallelization of Garfield++ and neBEM to simulate space charge effects in RPCs. https://doi.org/10.1016/j.cpc.2023.108944

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kinematic Fitting of electromagnetic calorimeter data - an improved method

Kinematic fitting is widely used in particle physics experiments as a powerful tool to improve experimental resolutions, to suppress background and to provide selection criteria for the identification of specific reactions. Kinematic fitting methods, however, typically assume that the fitted quantities follow Gaussian distributions; an assumption which does not always hold. This is particularly true for energy measurements from electromagnetic calorimeters. This issue can largely be overcome by performing a transformation of the non-Gaussian variables into variables which follow a Gaussian distribution. The new adapted kinematic fitting procedure allows to better account for the non-Gaussian nature of the measured calorimeter energies, at the same time improving the accuracy and robustness of the kinematic fit. This leads to improved pull and confidence-level distributions of the kinematic fit as well as improved invariant mass distributions and signal-to-background ratios in the final event sample.

physics.ins-det

Radiation hardness characterization of SiPM sensors for Low Earth Orbit space missions

This work presents a comprehensive radiation hardness characterization of SiPM devices for space-based applications: FBK NUV-HD-MT and NUV-HD-LowCT (1$\times$1, 3$\times$3, and 6$\times$6~mm$^2$) and Hamamatsu S14160 MPPCs with equivalent active areas. Total Ionizing Dose (TID) tests were performed at the ESA/ESTEC Co-60 facility with a level of dose up to 20~krad in silicon, while displacement damage effects were evaluated using 100~MeV protons with a fluence up to $1.12\times10^{11}$~p/cm$^2$ at the Paul Scherrer Institute. Radiation damage in SiPMs manifests through two main mechanisms: ionizing energy loss and non-ionizing energy loss (NIEL), which increases dark current and dark count rate. In this work, breakdown voltage, dark current, and quenching resistance were systematically measured as functions of accumulated dose and fluence. Gain and dark count rates were indirectly measured from the characterized electrical parameters. Both technologies exhibit remarkable stability of most of the functional parameters across all dose levels, while dark current shows predictable increases significantly more pronounced under proton irradiation due to displacement damage. Based on these results, both FBK and Hamamatsu devices are confirmed suitable for Low Earth Orbit (LEO) mission environment.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det