Search arXivSearch

arXiv · 2211.13214

Costs and benefits of automation for astronomical facilities

Abstract

The Observatorio Astrofísico de Javalambre (OAJ†1) in Spain is a young astronomical facility, conceived and developed from the beginning as a fully automated observatory with the main goal of optimizing the processes in the scientific and general operation of the Observatory. The OAJ has been particularly conceived for carrying out large sky surveys with two unprecedented telescopes of unusually large fields of view (FoV): the JST/T250, a 2.55m telescope of 3deg field of view, and the JAST/T80, an 83cm telescope of 2deg field of view. The most immediate objective of the two telescopes for the next years is carrying out two unique photometric surveys of several thousands square degrees, J-PAS†2 and J-PLUS†3, each of them with a wide range of scientific applications, like e.g. large structure cosmology and Dark Energy, galaxy evolution, supernovae, Milky Way structure, exoplanets, among many others. To do that, JST and JAST are equipped with panoramic cameras under development within the J-PAS collaboration, JPCam and T80Cam respectively, which make use of large format (~ 10k x 10k) CCDs covering the entire focal plane. This paper describes in detail, from operations point of view, a comparison between the detailed cost of the global automation of the Observatory and the standard automation cost for astronomical facilities, in reference to the total investment and highlighting all benefits obtained from this approach and difficulties encountered. The paper also describes the engineering development of the overall facilities and infrastructures for the fully automated observatory and a global overview of current status, pinpointing lessons learned in order to boost observatory operations performance, achieving scientific targets, maintaining quality requirements, but also minimizing operation cost and human resources.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A. Yanes-Díaz, S. Rueda-Teruel, R. Bello, D. Lozano-Pérez, M. Royo-Navarro, T. Civera, M. Domínguez-Martínez, N. Martínez-Olivar, S. Chueca, C. Iñiguez, A. Marin-Franch, F. Rueda-Teruel, G. López-Alegre, S. Bielsa, J. Muñoz-Maudos, H. Rueda-Asensio, A. Muñoz-Teruel, D. Garcés-Cubel, I. Soriano-Laguía, M. Almarcegui-Gracia, A. J. Cenarro, M. Moles, D. Cristobal-Hornillos, J. Varela, A. Ederoclite, H. Vázquez Ramió, M. C. Díaz-Martín, R. Iglesias-Marzoa, J. Castillo, A. López-Sainz, J. Hernández-Fuertes, D. Muniesa-Gallardo, A. Moreno-Signes, A. Hernán-Caballero, C. López-Sanjuan, A. del Pino, M. Akhlaghi, I. Pintos-Castro, J. Fernández-Ontiveros, F. Hernández-Pérez, S. Pyrzas, R. Infante-Sainz, T. Kuutma, D. Lumbreras-Calle, N. Maícas-Sacristán, J. Lamadrid-Gutierrez, F. López-Martínez, P. Galindo-Guil, E. Lacruz-Calderón, L. Valdivielso-Casas, M. Aguilar-Martín, S. Eskandarlou, A. Domínguez-Fernández, F. Arizo-Borillo, S. Vaquero-Valer, I. Muñoz-Igado, M. Alegre-Sánchez, G. Julián-CaballeroDeEspaña, A. Romero, D. Casinos-Cardo. 2022-11-24. Costs and benefits of automation for astronomical facilities. https://doi.org/10.1117/12.2626105

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM