Search arXivSearch

arXiv · 2212.03627

GPU propagation and visualisation of particle collisions with ALICE magnetic field model

Abstract

The ALICE Collaboration at CERN developed a 3D visualisation tool capable of displaying a representation of collected collision data (particle trajectories, clusters and calorimeter towers) called the Event Display. The Event Display is constantly running in the ALICE Run Control Center as part of the Quality Assurance system, providing the monitoring personnel with visual cues about possible problems of both hardware and software components during periods of data gathering. In the software, particle trajectories (which are curved due to presence of magnetic field inside the detector) are generated from physical parameters of detected particles, such as electrical charge and momentum. Previously this process in the Event Display used a uniform, constant magnetic field for these calculations, which differs from the spatial variations of the real magnetic field and does not model one of the two magnets used in the detector. Recently, a detailed model of ALICE magnetic field was made available as a shader program for execution on the GPU. In this work we attempt to implement the reconstruction algorithm in a shader form as well, allowing us to combine it with the detailed model to create a full solution for rendering trajectories from collision event data directly on the GPU. This approach has several possible advantages, such as better performance and the ability to alter the magnetic field properties in real-time. This was not previously done for ALICE and as such could be used in the future to upgrade the Event Display.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Piotr Nowakowski, Przemysław Rokita, Łukasz Graczykowski. 2023-09-22. GPU propagation and visualisation of particle collisions with ALICE magnetic field model. https://doi.org/10.1016/j.cpc.2023.108912

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kinematic Fitting of electromagnetic calorimeter data - an improved method

Kinematic fitting is widely used in particle physics experiments as a powerful tool to improve experimental resolutions, to suppress background and to provide selection criteria for the identification of specific reactions. Kinematic fitting methods, however, typically assume that the fitted quantities follow Gaussian distributions; an assumption which does not always hold. This is particularly true for energy measurements from electromagnetic calorimeters. This issue can largely be overcome by performing a transformation of the non-Gaussian variables into variables which follow a Gaussian distribution. The new adapted kinematic fitting procedure allows to better account for the non-Gaussian nature of the measured calorimeter energies, at the same time improving the accuracy and robustness of the kinematic fit. This leads to improved pull and confidence-level distributions of the kinematic fit as well as improved invariant mass distributions and signal-to-background ratios in the final event sample.

physics.ins-det

Radiation hardness characterization of SiPM sensors for Low Earth Orbit space missions

This work presents a comprehensive radiation hardness characterization of SiPM devices for space-based applications: FBK NUV-HD-MT and NUV-HD-LowCT (1$\times$1, 3$\times$3, and 6$\times$6~mm$^2$) and Hamamatsu S14160 MPPCs with equivalent active areas. Total Ionizing Dose (TID) tests were performed at the ESA/ESTEC Co-60 facility with a level of dose up to 20~krad in silicon, while displacement damage effects were evaluated using 100~MeV protons with a fluence up to $1.12\times10^{11}$~p/cm$^2$ at the Paul Scherrer Institute. Radiation damage in SiPMs manifests through two main mechanisms: ionizing energy loss and non-ionizing energy loss (NIEL), which increases dark current and dark count rate. In this work, breakdown voltage, dark current, and quenching resistance were systematically measured as functions of accumulated dose and fluence. Gain and dark count rates were indirectly measured from the characterized electrical parameters. Both technologies exhibit remarkable stability of most of the functional parameters across all dose levels, while dark current shows predictable increases significantly more pronounced under proton irradiation due to displacement damage. Based on these results, both FBK and Hamamatsu devices are confirmed suitable for Low Earth Orbit (LEO) mission environment.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det