Search arXivSearch

arXiv · 2212.12791

CUBES: a UV spectrograph for the future

Abstract

In spite of the advent of extremely large telescopes in the UV/optical/NIR range, the current generation of 8-10m facilities is likely to remain competitive at ground-UV wavelengths for the foreseeable future. The Cassegrain U-Band Efficient Spectrograph (CUBES) has been designed to provide high-efficiency (>40%) observations in the near UV (305-400 nm requirement, 300-420 nm goal) at a spectral resolving power of R>20,000, although a lower-resolution, sky-limited mode of R ~ 7,000 is also planned. CUBES will offer new possibilities in many fields of astrophysics, providing access to key lines of stellar spectra: a tremendous diversity of iron-peak and heavy elements, lighter elements (in particular Beryllium) and light-element molecules (CO, CN, OH), as well as Balmer lines and the Balmer jump (particularly important for young stellar objects). The UV range is also critical in extragalactic studies: the circumgalactic medium of distant galaxies, the contribution of different types of sources to the cosmic UV background, the measurement of H2 and primordial Deuterium in a regime of relatively transparent intergalactic medium, and follow-up of explosive transients. The CUBES project completed a Phase A conceptual design in June 2021 and has now entered the Phase B dedicated to detailed design and construction. First science operations are planned for 2028. In this paper, we briefly describe the CUBES project development and goals, the main science cases, the instrument design and the project organization and management.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. Covino, S. Cristiani, J. M. Alcala', S. H. P. Alencar, S. A. Balashev, B. Barbuy, N. Bastian, U. Battino, L. Bissell, P. Bristow, A. Calcines, G. Calderone, P. Cambianica, R. Carini, B. Carter, S. Cassisi, B. V. Castilho, G. Cescutti, N. Christlieb, R. Cirami, R. Conzelmann, I. Coretti, R. Cooke, G. Cremonese, K. Cunha, G. Cupani, A. R. da Silva, D. D'Auria, V. De Caprio, A. De Cia, H. Dekker, V. D'Elia, G. De Silva, M. Diaz, P. Di Marcantonio, V. D'Odorico, H. Ernandes, C. Evans, A. Fitzsimmons, M. Franchini, B. Gaensicke, M. Genoni, R. E. Giribaldi, C. Gneiding, A. Grazian, C. J. Hansen, J. Hopgood, J. Kosmalski, F. La Forgia, P. La Penna, M. Landoni, M. Lazzarin, D. Lunney, W. Maciel, W. Marcolino, M. Marconi, A. Migliorini, C. Miller, A. Modigliani, P. Noterdaeme, L. Oggioni, C. Opitom, G. Pariani, B. Pilecki, S. Piranomonte, A. Quirrenbach, E. M. A. Redaelli, C. B. Pereira, S. Randich, S. Rossi, R. Sanchez-Janssen, M. Schoeller, W. Seifert, R. Smiljanic, C. Snodgrass, O. Squalli, I. Stilz, J. Stuermer, A. Trost, E. Vanzella, P. Ventura, O. Verducci, C. Waring, S. Watson, M. Wells, D. Wright, T. Zafar, A. Zanutta, G. Zins. 2022-12-24. CUBES: a UV spectrograph for the future. https://arxiv.org/abs/2212.12791

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM