Search arXivSearch

arXiv · 2301.02880

A Simulation Study for the Expected Performance of Sharjah-Sat-1 payload improved X-Ray Detector (iXRD) in the Orbital Background Radiation

Abstract

Sharjah-Sat-1 is a 3U cubesat with a CdZnTe based hard X-ray detector, called iXRD (improved X-ray Detector) as a scientific payload with the primary objective of monitoring bright X-ray sources in the galaxy. We investigated the effects of the in-orbit background radiation on the iXRD based on Geant4 simulations. Several background components were included in the simulations such as the cosmic diffuse gamma-rays, galactic cosmic rays (protons and alpha particles), trapped protons and electrons, and albedo radiation arising from the upper layer of the atmosphere. The most dominant component is the albedo photon radiation which contributes at low and high energies alike in the instrument energy range of 20 keV - 200 keV. On the other hand, the cosmic diffuse gamma-ray contribution is the strongest between 20 keV and 60 keV in which most of the astrophysics source flux is expected. The third effective component is the galactic cosmic protons. The radiation due to the trapped particles, the albedo neutrons, and the cosmic alpha particles are negligible when the polar regions and the South Atlantic Anomaly region are excluded in the analysis. The total background count rates are ~0.36 and ~0.85 counts/s for the energy bands of 20 - 60 keV and 20 - 200 keV, respectively. We performed charge transportation simulations to determine the spectral response of the iXRD and used it in sensitivity calculations as well. The simulation framework was validated with experimental studies. The estimated sensitivity of 180 mCrab between the energy band of 20 keV - 100 keV indicates that the iXRD could achieve its scientific goals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ali M. Altingun, Emrah Kalemci, Efe Oztaban. 2023-01-07. A Simulation Study for the Expected Performance of Sharjah-Sat-1 payload improved X-Ray Detector (iXRD) in the Orbital Background Radiation. https://doi.org/10.1007/s10686-022-09885-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det