Search arXivSearch

arXiv · 2301.03912

MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate

Abstract

Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The "MALTA-Czochralski (MALTA-Cz)" full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granularity, high hit-rate capability, fast response time and superior radiation tolerance. The small pixel size ($36.4\times 36.4$~$μ$m$^2$) provides high spatial resolution. Its asynchronous readout architecture is designed for high hit-rates and fast time response in triggered and trigger-less detector applications. The readout architecture is designed to stream all hit data to the multi-channel output which allows an off-sensor trigger formation and the use of hit-time information for event tagging. The sensor manufacturing has been optimised through process adaptation and special implant designs to allow the manufacturing of small electrode DMAPS on thick high-resistivity p-type Czochralski substrate. The special processing ensures excellent charge collection and charge particle detection efficiency even after a high level of radiation. Furthermore the special implant design and use of a Czochralski substrate improves the sensor's time resolution. This paper presents a summary of sensor design optimisation through process and implant choices and TCAD simulation to model the signal response. Beam and laboratory test results on unirradiated and irradiated sensors have shown excellent detection efficiency after a dose of $2\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$. The time resolution of the sensor is measured to be $σ=2$~ns.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H. Pernegger, P. Allport, D. V. Berlea, A. Birman, D. Bortoletto, C. Buttar, E. Charbon, F. Dachs, V. Dao, H. Denizli, D. Dobrijevic, M. Dyndal, A. Fenigstein, L. Flores Sanz de Acedo, P. Freeman, A. Gabrielli, M. Gazi, L. Gonella, V. Gonzalez, G. Gustavino, A. Haim, T. Kugathasan, M. LeBlanc, M. Munker, K. Y. Oyulmaz, F. Piro, P. Riedler, H. Sandaker, E. J. Schioppa, A. Sharma, W. Snoeys, C. Solans Sanchez, T. Suligoj, E. Toledano, M. van Rijnbach, M. Vazquez Nunez, J. Weick, S. Worm, A. M. Zoubir. 2023-09-13. MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate. https://doi.org/10.1088/1748-0221%2F18%2F09%2Fp09018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det