Search arXivSearch

arXiv · 2302.13859

Propagation Constant Measurement Based on a Single Transmission Line Standard Using a Two-port VNA

Abstract

This study presents a new method for measuring the propagation constant of transmission lines using a single line standard and without prior calibration of a two-port vector network analyzer (VNA). The method provides accurate results by emulating multiple line standards of the multiline calibration method. Each line standard is realized by sweeping an unknown network along a transmission line. The network need not be symmetric or reciprocal, but must exhibit both transmission and reflection. We performed measurements using a slab coaxial airline and repeated the measurements on three different VNAs. The measured propagation constant of the slab coaxial airline from all VNAs is nearly identical. By avoiding disconnecting or moving the cables, the proposed method eliminates errors related to repeatability of connectors, resulting in improved broadband traceability to SI units.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ziad Hatab, Arezoo Abdi, Gregor Steinbauer, Michael Ernst Gadringer, Wolfgang Bösch. 2023-03-08. Propagation Constant Measurement Based on a Single Transmission Line Standard Using a Two-port VNA. https://doi.org/10.3390/s23094548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det