Low Overhead RF Impedance Measurement by Using Periodic Structures

Abstract

Due to the need for higher reliability and performance from RF circuits, multi-port reflectometers are increasingly used as low-overhead impedance monitors. In this work, using periodic structures as multi-ports is proposed. Periodic structures impose a new constraint on the multi-port theory and simplify it significantly. This simplification leads to closed form solution for calibration and measurement procedures. The closed-form solution also shows that any arbitrary periodic structure will always have a unique solution for both procedures. Therefore, the proposed technique does not rely on frequency-dependent behavior of devices, such as directivity and phase shift to measure impedance. This fact leads to increased bandwidth and simplified design procedure. In addition, proposed multi-port structures can be calibrated by using fewer known loads than existing multi-port techniques. This fact, coupled with the closed-form solution, reduces computation overhead and test time. The theory and its robustness against non-idealities, such as part-to-part variation, are verified with Monte-Carlo simulations. A practical embodiment of the technique is demonstrated with EM simulations and hardware experiments. In this embodiment, the multi-port structure is embedded into an LC matching network. Hardware experiments show that the embedded multi-port structure can measure test loads with high accuracy from 1.5 GHz to 3.5 GHz, without degrading matching network performance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Muslum Emir Avci, Sule Ozev. 2023-03-13. Low Overhead RF Impedance Measurement by Using Periodic Structures. https://doi.org/10.1109/tmtt.2023.3257641

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det