Search arXivSearch

arXiv · 2305.07291

Impact of errors in the magnetic field measurement on the precision determination of neutrino oscillation parameters at the proposed ICAL detector at INO

Abstract

The magnetised iron calorimeter (ICAL) detector proposed at the India-based Neutrino Observatory will be a 51 kton detector made up of 151 layers of 56 mm thick soft iron with 40 mm air gap in between where the RPCs, the active detectors, will be placed. The main goal of ICAL is to make precision measurements of the neutrino oscillation parameters using the atmospheric neutrinos as source. The charged current interactions of the atmospheric muon neutrinos and anti-neutrinos in the detector produce charged muons. The magnetic field, with a maximum value of $\sim$ 1.5 T in the central region of ICAL, is a critical component since it will be used to distinguish the charges and determine the momentum and direction of these muons. It is difficult to measure the magnetic field inside the iron. The existing methods can only estimate the internal field and hence will be prone to error. This paper presents the first simulations study of the effect of errors in the measurement of the magnetic field in ICAL on its physics potential, especially the neutrino mass ordering and precision measurement of oscillation parameters in the 2--3 sector. The study is a GEANT4-based analysis, using measurements of the magnetic field at the prototype ICAL detector. We find that there is only a small effect on the determination of the mass ordering. While local fluctuations in the magnetic field measurement are well-tolerated, calibration errors must remain well within 5\% to retain good precision determination of the parameters $\sin^2θ_{23}$ and $Δm^2_{32}$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Honey Khindri, D. Indumathi, Lakshmi S. Mohan. 2023-05-15. Impact of errors in the magnetic field measurement on the precision determination of neutrino oscillation parameters at the proposed ICAL detector at INO. https://arxiv.org/abs/2305.07291

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Exploring the Singlino-dominated Thermal Neutralino Dark Matter in the $Z_3$ invariant NMSSM

We examine the parameter space of the Next to Minimal Supersymmetric Standard Model (NMSSM) with Singlino-dominated neutralino $\widetildeχ_1^0$ as the lightest supersymmetric particle (LSP). Our study focuses on identifying the regions within this parameter space that produce a thermal relic abundance of $\widetildeχ_1^0$ smaller than the observed cold dark matter relic density while remaining consistent with constraints from LEP measurements, low-energy experiments, Higgs measurements, LHC data, and dark matter direct detection experiments. We identify the dominant annihilation modes of the LSP neutralino across varying LSP mass ranges $\sim \mathcal{O}(1)-\mathcal{O}(10^{3})~$GeV. Furthermore, we conduct a benchmark study to assess the production rates of triple-boson final states emerging from direct electroweakino pair production at the LHC. Drawing insights from these findings, we perform a detailed collider analysis to explore the future potential of probing the triple-boson final states involving a light Higgs boson at the high-luminosity LHC (HL-LHC).

hep-ph

Unveiling the Collins-Soper kernel in inclusive DIS at threshold

We revisit the factorization of inclusive deep inelastic scattering (DIS) near the kinematic threshold in terms of collinear, off-light-cone operators. At threshold, particle production develops around two opposite near-light-cone directions in close analogy with transverse-momentum-dependent semi-inclusive DIS. The Collins-Soper kernel then emerges as the universal function governing the rapidity evolution of the relevant parton correlators in both cases. Our new framework also clarifies outstanding issues related to soft radiation and rapidity divergences at threshold.

hep-ph

Novel Light Dark Matter Detection with Quantum Parity Detector Using Qubit Arrays

We present the design and the sensitivity reach of the Qubit-based Light Dark Matter detection experiment. We propose the novel two-chip design to reduce signal dissipation, with quantum parity measurement to enhance single-phonon detection sensitivity. We demonstrate the performance of the detector with full phonon and quasiparticle simulations. The experiment is projected to detect $\gtrsim 30$ meV energy deposition with nearly $100\%$ efficiency and high energy resolution. The sensitivity to $m_χ\gtrsim 0.01$ MeV dark matter scattering cross section is expected to be advanced by orders of magnitude for both light and heavy mediators, and similar improvements will be achieved for axion and dark photon absorption in the $0.04$-$0.2$ eV mass range.

hep-ph