Search arXivSearch

arXiv · 2306.10820

The SiFi-CC detector for beam range monitoring in proton therapy -- characterization of components and a prototype detector module

Abstract

The following thesis presents research which constitutes the first steps towards the construction of a novel SiFi-CC detector intended for real-time monitoring of proton therapy. The detector construction will be based on inorganic scintillating fibers and silicon photomultipliers. The scope of the presented thesis includes the design optimization of the components of the proposed detector, as well as the construction, characterization, and tests of a prototype. The design optimization comprised an extensive systematic comparison of chosen inorganic scintillating materials, different types of scintillator surface modifications (wrappings and coatings), and different types of interface materials ensuring optical contact between the scintillators and the photodetector. The propagation of scintillating light in all investigated samples was described using two models: the exponential light attenuation model (ELA), and the exponential light attenuation model with light reflection (ELAR). The two models yielded the corresponding methods for energy and position reconstruction. Furthermore, the samples were investigated for energy and position resolution, light collection, and timing properties. Based on the results obtained from the optimization study, the detector prototype was constructed. Prototype tests were performed with two different photodetectors and data acquisition systems. The performance of the prototype was evaluated using the same metrics as in the case of single-fiber measurements. The best results were obtained in measurements with Philips Digital Photon Counting photosensor and the Hyperion platform, yielding a position resolution of 33.38 mm and an energy resolution of 7.73 %. The results obtained are satisfactory and sufficient for the successful operation of the proposed SiFi-CC detector.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Katarzyna Rusiecka. 2023-06-19. The SiFi-CC detector for beam range monitoring in proton therapy -- characterization of components and a prototype detector module. https://arxiv.org/abs/2306.10820

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det