Search arXivSearch

arXiv · 2307.15506

Improving image quality of sparse-view lung tumor CT images with U-Net

Abstract

Background: We aimed at improving image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determining the best tradeoff between number of views, IQ, and diagnostic confidence. Methods: CT images from 41 subjects aged 62.8 $\pm$ 10.6 years (mean $\pm$ standard deviation), 23 men, 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used. Results: The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images. Conclusions: Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Annika Ries, Tina Dorosti, Johannes Thalhammer, Daniel Sasse, Andreas Sauter, Felix Meurer, Ashley Benne, Tobias Lasser, Franz Pfeiffer, Florian Schaff, Daniela Pfeiffer. 2024-02-14. Improving image quality of sparse-view lung tumor CT images with U-Net. https://doi.org/10.1186/s41747-024-00450-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Lifelong Learning of Video Diffusion Models From a Single Video Stream

Video diffusion models can enable embodied agents to anticipate plausible futures from the recent past, but they are typically trained offline on curated datasets--a mismatch with the agents' learning setup at deployment: online, from a single video stream that sequentially outputs one frame at a time. We bridge this training gap and demonstrate that training autoregressive video diffusion models from such a stream, resembling the experience of embodied agents, is not only possible but can also perform comparably to standard offline training given the same number of gradient steps. We find that this robustness to video stream autocorrelation and nonstationarity can be achieved using experience replay methods that retain a subset of the video stream. To support training and evaluation in this setting, we introduce five new datasets for streaming lifelong generative video modeling: Lifelong Bouncing Balls (O), Lifelong Bouncing Balls (C), Lifelong 3D Maze, Lifelong Drive, and Lifelong PLAICraft, each consisting of one million consecutive frames from environments of increasing complexity. Together, our datasets and experiments lay the groundwork for video generative models and world models that continuously learn from single-sensor video streams rather than fixed datasets.

cs.CV

Bayesian Fusion of Active Contour Models and ConvNet Priors for Standing Dead Tree Segmentation

Instance segmentation is a core computer vision task with great practical significance. Recent advances, driven by large-scale benchmark datasets, have yielded good general-purpose Convolutional Neural Network (CNN)-based methods. Natural Resource Monitoring (NRM) utilizes remote sensing imagery with generally known scale and containing multiple overlapping instances of the same class, wherein the object contours are jagged and highly irregular. This is in stark contrast with the regular man-made objects found in classic benchmark datasets. We address this problem and propose a novel instance segmentation method geared towards NRM imagery. We formulate the problem as Bayesian maximum a posteriori inference which, in learning the individual object contours, incorporates shape, location, and position priors from state-of-the-art CNN architectures, driving a simultaneous level-set evolution of multiple object contours. We employ loose coupling between the CNNs that supply the priors and the active contour process, allowing a drop-in replacement of new network architectures. Moreover, we introduce a novel prior for contour shape, namely, a class of Deep Shape Models based on architectures from Generative Adversarial Networks (GANs). These Deep Shape Models are in essence a non-linear generalization of the classic Eigenshape formulation. In experiments, we tackle the challenging, real-world problem of segmenting individual dead tree crowns and delineating precise contours. We compare our method to two leading general-purpose instance segmentation methods - Mask R-CNN and K-net - on color infrared aerial imagery. Results show our approach to significantly outperform both methods in terms of reconstruction quality of tree crown contours. Furthermore, use of the GAN-based deep shape model prior yields significant improvement of all results over the vanilla Eigenshape prior.

cs.CV

Sonicmesh: Enhancing 3D Human Mesh Reconstruction in Vision-Impaired Environments With Acoustic Signals

3D human mesh reconstruction (HMR) from RGB images often degrades under poor illumination, occlusion, and non-line-of-sight conditions. Acoustic sensing provides complementary spatial cues but suffers from low spatial resolution. We propose SonicMesh, which, to the best of our knowledge, is the first acoustic--visual framework for robust 3D human mesh reconstruction. SonicMesh first converts ultrasonic echoes into range--azimuth acoustic images through an Inverse Synthetic Aperture Radar (ISAR)-based imaging process. It then introduces a cross-dimensional anatomical registration module that maps modality-specific 2D joint features into a common canonical 3D human space. The registered anatomical representations are further integrated with acoustic and visual features through a two-stage fusion network for final mesh reconstruction. Experiments demonstrate that SonicMesh achieves accurate and robust 3D human reconstruction across normal, poor-light, occluded, and non-line-of-sight environments, consistently outperforming existing RGB-, radio-frequency (RF)-, and mmWave-based approaches under challenging sensing conditions.

cs.CV