Search arXivSearch

arXiv · 2308.01306

A Neutrino Detector Design for Safeguarding Small Modular Reactors

Abstract

Nuclear reactors have long been a favored source for antineutrino measurements for estimates of power and burnup. With appropriate detector parameters and background rejection, an estimate of the reactor power can be derived from the measured antineutrino event rate. Antineutrino detectors are potentially attractive as a safeguards technology that can monitor reactor operations and thermal power from a distance. Advanced reactors have diverse features that may present challenges for current safeguards methods. By comparison, neutrino detectors offer complementary features, including a remote, continuous, unattended, and near-real-time monitoring capability, that may make them useful for safeguarding certain classes of advanced reactors. This study investigates the minimum depth and size of an antineutrino detector for a SMR to meet safeguards needs for advanced reactors. Extrapolating performance from several prior reactor antineutrino experiments, this study uses an analytical approach to develop a possible design for a remote antineutrino-based monitoring device.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Emma Houston, Oluwatomi Akindele, Marc Bergevin, Adam Bernstein, Steven Dazley, Sandra Bogetic. 2023-08-02. A Neutrino Detector Design for Safeguarding Small Modular Reactors. https://arxiv.org/abs/2308.01306

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det