Search arXivSearch

arXiv · 2308.04652

Drop size characteristics of sprays emanating from circular and non-circular orifices in the atomization regime

Abstract

Traditionally, circular orifices have been used for generating aerosols, however in recent times non-circular orifices are being considered due to their superior atomization and mixing features. In this work, we experimentally investigate spray morphology and drop size characteristics of kerosene (Jet A-1) jets issuing from three non-circular orifices geometries (elliptic, triangular and, square) and one circular orifice with the same exit cross sectional area. Our results show an unexpected and yet unreported coarsening of atomization for non-circular orifice jets quantified by an increase in the Sauter Mean Diameter (SMD) at all tested exit velocities represented by the liquid Weber number, $We_l$. We attribute this to two distinct spray morphologies: filament and core breakup which generate large size liquid structures identified as filaments and ligaments, noticeable in non-circular orifices jets compared to circular orifice jets. On exploring this further by undertaking an examination of the drop size volume probability distribution at lower $We_l$ corresponding to the location marking the end of primary breakup we see a bimodality due to a dominant distribution of fragments of small and larger sizes owing to the spray morphology. At higher $We_l$ and larger distances from the injector exit we observe the bimodality converts to a unimodal distribution for all orifice jets with a single peak situated at lower drop diameters. Filament breakup is reasoned to be the cause of higher number of smaller drop sizes in triangular sprays among all non-circular orifice jets while thinner filaments in circular orifice sprays lead to smaller drop sizes compared to their triangular counterparts showing the same breakup morphology. We expect our results to help applications as diverse as engine fuel combustion, pharmaceutical sprays and CO$_2$ capture by NaOH sprays.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K. R. Rajesh, V. Kulkarni, S. Vankeswaram, R. Sakthikumar, S. Deivandren. 2023-08-09. Drop size characteristics of sprays emanating from circular and non-circular orifices in the atomization regime. https://doi.org/10.1016/j.jaerosci.2023.106245

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mathematical modeling on peristaltic flow of a Prandtl fluid with effects of slip conditions and inclined magnetic field

The manuscript provides a description of a theoretical analysis of a non-Newtonian Prandtl fluid subject to peristaltic flow through an inclined asymmetric channel. We explore the effect of an inclined magnetic field on the peristaltic flow. This is relevant for applications involving fluid flow in narrow, inclined (tilted) tubes similar to blood vessels or the digestive system. The model also includes thermodynamic aspects such as heat diffusion (the Soret effect) and viscous dissipation resulting from wall-fluid slip conditions, which may help optimize medical devices such as lab-on-a-chip systems and dialysis machines. In this study, the concentration of a generic chemical, temperature, and fluid velocity are taken into account through mass, heat, and momentum balances, respectively. The solution is approximated using numerical techniques suitable for long wavelengths (low frequency) and low Reynolds numbers. The study also discusses trapping phenomena, which are crucial from a clinical point of view. The developed insights can improve the understanding of physiological flows in the gastrointestinal tract and blood vessels. By understanding how the fluid moves and how particles are trapped, these insights may contribute to the design of improved medical pumps and artificial organs. Graphical visualizations are provided for the fluid velocity profile, temperature distribution, and concentration of a generic chemical. Furthermore, the numerical results are validated through comparison with a closed-form solution from a benchmark problem.

physics.flu-dyn

Discovery of a dispersion model at high Peclet numbers

Peclet number characterises the transition from classical Taylor-Aris dispersion to convection-dominated longitudinal solute transport, with the classical model becoming inadequate at extremely high radial Peclet number $Pe_r$. We develop a novel explicit-closure one-dimensional (1-D) effective dispersion model for this high-$Pe_r$ regime by introducing two closure coefficients, $θ_u$ and $θ_d$, whose functional structures are identified using low-frequency transfer-function matching and a modified Kolmogorov-Arnold network (KAN). The resulting model captures the transition from classical Taylor-Aris dispersion at low $Pe_r$ to convection-dominated dispersion at high $Pe_r$. Analysis reveals that, in the high-$Pe_r$ regime, axial transport is redistributed between the effective convection flux and the dispersive flux, resulting in a reduced macroscopic convection velocity. Numerical validation demonstrates close agreement with the convection-diffusion model over the investigated high-$Pe_r$ conditions, while the classical Taylor-Aris model exhibits substantial deviations. Application of the proposed model to averaged flow velocity inversion further demonstrates improved velocity estimation, particularly in the high-$Pe_r$ regime. These results highlight the importance of accounting for non-classical dispersion for reliable contrast-agent-based arterial blood flow velocimetry and provide new insight into high-$Pe_r$ mass transport.

physics.flu-dyn

Optimization of fluid mixing by reinforcement learning using limit cycles of a dynamical system

We propose a method to overcome the difficulties encountered when applying reinforcement learning to fluid mixing processes. The proposed method has two main features: (i) it does not require detailed measurements of the flow state, and (ii) by effectively exploiting a stable limit cycle of a two-dimensional dynamical system (the Li'enard system), it can stably perform optimization without imposing explicit constraints on the control parameters. As an illustrative example, we optimize a process in which a fluid contained in a cylindrical vessel is mixed by periodically rotating the vessel. The resulting optimal vessel motion is physically reasonable: it reverses its direction of rotation before a solid-body rotation state is established. Furthermore, even when the fluid viscosity increases with time during the mixing process, the method can continuously adapt the control parameters to the changing viscosity.

physics.flu-dyn