Alteration of skeletal muscle energy metabolism assessed by 31P MRS in clinical routine, part 2: Clinical application

Abstract

Background: In this second part of a two-part paper, we intend to demonstrate the impact of the previously proposed advanced quality control pipeline. To understand its benefit and challenge the proposed methodology in a real scenario, we chose to compare the outcome when applying it to the analysis of two patient populations with a significant but highly different types of fatigue: COVID19 and multiple sclerosis (MS). Experimental: 31P-MRS was performed on a 3T clinical MRI, in 19 COVID19 patients, 38 MS patients, and 40 matched healthy controls. Dynamic acquisitions using an MR-compatible ergometer ran over a rest(40s), exercise(2min), and a recovery phase(6min). Long and short TR acquisitions were also made at rest for T1 correction. The advanced data quality control pipeline presented in part 1 is applied to the selected patient cohorts to investigate its impact on clinical outcomes. We first used power and sample size analysis to estimate objectively the impact of adding QCS. Then, comparisons between patients and healthy control groups using validated QCS were performed using unpaired T-tests or Mann-Whitney tests (p<0.05).Results: The application of the QCS resulted in increased statistical power, changed the values of several outcome measures, and reduced variability (SD). A significant difference was found between the T1PCr and T1Pi of MS patients and healthy controls. Furthermore, the use of a fixed correction factor led to systematically higher estimated concentrations of PCr and Pi than when using individually corrected factors. We observed significant differences between the two patient populations and healthy controls for resting [PCr] -- MS only, [Pi], [ADP], [H2PO4-] and pH -- COVID19 only, and post-exercise [PCr],[Pi] and [H2PO4-] - MS only. The dynamic indicators $τ$PCr, $τ$Pi, ViPCr and Vmax were reduced for COVID19 and MS patients compared to controls. Conclusion: Our results show that QCS in dynamic 31P-MRS studies results in smaller data variability and therefore impacts study sample size and power. Although QCS resulted in discarded data and therefore reduced the acceptable data and subject numbers, this rigorous and unbiased approach allowed for proper assessment of muscle metabolites and metabolism in patient populations. The outcomes include an increased metabolite T1, which directly affect the T1 correction factor applied to the amplitudes of the metabolite, and a prolonged $τ$PCr indicating reduced muscle oxidative capacity for patients with MS and COVID19.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Antoine Naëgel, Hélène Ratiney, Jabrane Karkouri, Djahid Kennouche, Nicolas Royer, Jill M Slade, Jérôme Morel, Pierre Croisille, Magalie Viallon. 2023-09-21. Alteration of skeletal muscle energy metabolism assessed by 31P MRS in clinical routine, part 2: Clinical application. https://doi.org/10.1002/nbm.5031

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circulant ADMM-Net for Fast High-resolution DoA Estimation

This paper introduces CADMM-Net and CHADMM-Net, two deep neural networks for direction of arrival estimation within the least-absolute shrinkage and selection operator (LASSO) framework. These two networks are based on a structured deep unfolding of the alternating direction method of multipliers (ADMM) algorithm through the use of circulant as well as Hermitian-circulant matrices. Along with a computational complexity of $\mathcal{O}(N\log(N))$ per layer for the inference, where $N$ is the length of the dictionary $\mathbf{A}$, they additionally exhibit a memory footprint of $N$ and approximately half of $N$ for CADMMNet and CHADMM-Net, respectively, compared with $N^{2}$ for ADMM-Net. Furthermore, these structured networks exhibit a competitive performance against ADMM-Net, LISTA, TLISTA, and THLISTA with respect to the detection rate, the angular root-mean square error, and the normalized mean squared error.

eess.SP

BASIIS: Bistatic Angular Sampling and Interpolation for ISAC Setups

Integrated Sensing and Communications (ISAC) is a defining feature of 6G, extending cellular networks with radar-like sensing at limited additional overhead. In bistatic deployments, sensing requires coordinating the transmitter (TX) and receiver (RX) arrays to scan the Cartesian product of angle of departure and arrival, resulting in a four-dimensional sampling problem in the angular domain. This work establishes a complete angular sampling framework for bistatic ISAC, extending the DFT-based optimal-sampling methodology to the full azimuth and elevation domains of both arrays. We show that the bistatic geometry couples the TX and RX elevation angles, and represent this coupling through the ortho-baseline coarray, a virtual array that captures the joint elevation aperture of the array pair. From the coarray we derive a minimal sampling and interpolation scheme, near-lossless and realizable with any beamforming architecture. Monte Carlo simulations confirm the proposed minimal acquisition essentially equalizes the detection accuracy of dense oversampled imaging while acquiring 3 to 5 times fewer TX-RX direction pairs. This allows having bistatic operations with drastically reduced overhead on the radio resource usage of ISAC systems.

eess.SP

Centroid Angle Estimation of Multiple Scatterers Using Monopulse Radar with Frequency Diversity

The monopulse technique determines the angle of a target by comparing signals from two narrow beams, yielding a precise angular estimate with low complexity. However, it struggles to resolve multiple closely spaced scatterers within the same resolution cell. Existing methods for estimating multiple scatterer angles involve complex signal processing and system modifications. We propose an effective method to estimate the angular centroid of scatterers using the mode of monopulse angle estimates. A semi-analytic expression for the angle estimate distribution is derived, confirming that its mode aligns with the centroid. To enhance estimation accuracy, we employ frequency diversity to reduce sample correlation. Numerical results validate the advantages of the proposed method, demonstrating superior performance over conventional techniques with low complexity.

eess.SP