Alteration of skeletal muscle energy metabolism assessed by 31P MRS in clinical routine, part 1: Advanced Quality Control pipeline

Abstract

Background: Implementing a standardized 31P-MRS dynamic acquisition protocol to evaluate skeletal muscle energy metabolism and monitor muscle fatigability1,2, while being compatible with various longitudinal clinical studies on diversified patient cohorts, requires a high level of technicality and expertise. Furthermore, processing data to obtain reliable results also demands a great degree of expertise from the operator. In this two-part article, we present an advanced quality control approach for data acquired using a dynamic 31P-MRS protocol. The aim is to provide decision support to the operator in order to assist in data processing and obtain reliable results based on objective criteria. We present first in part one, an advanced data quality control (QC) approach of a dynamic 31P-MRS protocol. Part two is an impact study demonstrating the added value of the QC approach to explore clinical results derived from two patient populations with significant fatigue: COVID19 and multiple sclerosis (MS). Experimental: 31P-MRS was performed on a 3T clinical MRI in 175 subjects from clinical and healthy control populations conducted in a University Hospital. An advanced data QC Score (QCS) was developed using multiple objective criteria. The criteria were based on current recommendations from the literature enriched by new proposals based on clinical experience. The QCS was designed to indicate valid and corrupt data and guide necessary objective data editing to extract as much valid physiological data as possible. Dynamic acquisitions using an MR-compatible ergometer ran over a rest(40s), exercise(2min), and a recovery phase(6min). Results: Using QCS enabled rapid identification of subjects with data anomalies allowing the user to correct the data series or reject them partially or entirely as well as identify fully valid datasets. Overall, the use of the QCS resulted in the automatic classification of 45% of the subjects including 58 participants that had data with no criterion violation and 21 participants with violations that resulted in the rejection of all dynamic data. The remaining datasets were inspected manually with guidance allowing acceptance of full datasets from an additional 80 participants and recovery phase data from an additional 16 subjects. Overall, more anomalies occurred with patient data (35% of datasets) compared to healthy controls (15% of datasets). Conclusion: This paper describes typical difficulties encountered during the dynamic acquisition of 31P-MRS. Based on these observations, a standardized data quality control pipeline was created and implemented in both healthy and patient populations. The QC scoring ensures a standardized data rejection procedure and rigorous objective analysis of dynamic 31P-MRS data obtained from patients. The contribution of this methodology contributes to efforts made to standardize the practices of the 31P-MRS that has been underway for a decade, with the ultimate goal of making it an empowered tool for clinical research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Antoine Naëgel, Hélène Ratiney, Jabrane Karkouri, Djahid Kennouche, Nicolas Royer, Jill M Slade, Jérôme Morel, Pierre Croisille, Magalie Viallon. 2023-09-22. Alteration of skeletal muscle energy metabolism assessed by 31P MRS in clinical routine, part 1: Advanced Quality Control pipeline. https://doi.org/10.1002/nbm.5025

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circulant ADMM-Net for Fast High-resolution DoA Estimation

This paper introduces CADMM-Net and CHADMM-Net, two deep neural networks for direction of arrival estimation within the least-absolute shrinkage and selection operator (LASSO) framework. These two networks are based on a structured deep unfolding of the alternating direction method of multipliers (ADMM) algorithm through the use of circulant as well as Hermitian-circulant matrices. Along with a computational complexity of $\mathcal{O}(N\log(N))$ per layer for the inference, where $N$ is the length of the dictionary $\mathbf{A}$, they additionally exhibit a memory footprint of $N$ and approximately half of $N$ for CADMMNet and CHADMM-Net, respectively, compared with $N^{2}$ for ADMM-Net. Furthermore, these structured networks exhibit a competitive performance against ADMM-Net, LISTA, TLISTA, and THLISTA with respect to the detection rate, the angular root-mean square error, and the normalized mean squared error.

eess.SP

BASIIS: Bistatic Angular Sampling and Interpolation for ISAC Setups

Integrated Sensing and Communications (ISAC) is a defining feature of 6G, extending cellular networks with radar-like sensing at limited additional overhead. In bistatic deployments, sensing requires coordinating the transmitter (TX) and receiver (RX) arrays to scan the Cartesian product of angle of departure and arrival, resulting in a four-dimensional sampling problem in the angular domain. This work establishes a complete angular sampling framework for bistatic ISAC, extending the DFT-based optimal-sampling methodology to the full azimuth and elevation domains of both arrays. We show that the bistatic geometry couples the TX and RX elevation angles, and represent this coupling through the ortho-baseline coarray, a virtual array that captures the joint elevation aperture of the array pair. From the coarray we derive a minimal sampling and interpolation scheme, near-lossless and realizable with any beamforming architecture. Monte Carlo simulations confirm the proposed minimal acquisition essentially equalizes the detection accuracy of dense oversampled imaging while acquiring 3 to 5 times fewer TX-RX direction pairs. This allows having bistatic operations with drastically reduced overhead on the radio resource usage of ISAC systems.

eess.SP

Centroid Angle Estimation of Multiple Scatterers Using Monopulse Radar with Frequency Diversity

The monopulse technique determines the angle of a target by comparing signals from two narrow beams, yielding a precise angular estimate with low complexity. However, it struggles to resolve multiple closely spaced scatterers within the same resolution cell. Existing methods for estimating multiple scatterer angles involve complex signal processing and system modifications. We propose an effective method to estimate the angular centroid of scatterers using the mode of monopulse angle estimates. A semi-analytic expression for the angle estimate distribution is derived, confirming that its mode aligns with the centroid. To enhance estimation accuracy, we employ frequency diversity to reduce sample correlation. Numerical results validate the advantages of the proposed method, demonstrating superior performance over conventional techniques with low complexity.

eess.SP