Search arXivSearch

arXiv · 2310.00779

Neutron-induced fission reaction studies with minor actinides using a double Frisch grid fission detector

Abstract

Neutron-induced fission cross-section studies are being pursued with a double Frisch grid fission detector. We are working towards conducting neutron-induced fission cross-section measurements of high priority 241Am(n, f) and 244,245Cm(n, f) fission reactions in the energy range of 1-2000 keV. These measurements of high priority (n, f) reactions cross-sections from the OECD Nuclear Energy Agency High Priority Request List (HPRL), are identified as reactions that require improved data in the energy range of 1-2000 keV for the safe and economic design of next-generation fast nuclear reactors. The 7Li(p, n) reaction at various proton energies from 1.9 MeV to 3.6 MeV will be used to produce neutron flux to conduct neutron-induced fission cross-section studies. In the present special issue contribution paper, we are presenting the characterization study of the double Frisch grid fission detector. The detector is characterized with a 252Cf (spontaneous fission) source. The chamber consists of two cylindrical ionization sections in a back-to-back geometry sharing a common cathode. Each section consists of a cathode, guard rings, a grid, and an anode. The grids are made as a wire plane. The separation between the cathode and grid is 5.3 cm, and the grid to the anode is 1.2 cm. The source is mounted on a common cathode, and the chamber is operated at approximately 800 Torr pressure of P-10 gas mixture. The data acquisition with the digital data acquisition module CAEN N6725 is being set up and the preliminary analysis of the chamber performance suggests that the detector operation is good and stable. Further work with regard to employing trigger from the cathode and incorporating energy loss corrections are being pursued.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chandrabhan Yadav, Dvir Ben Simhon, Moshe Friedman. 2023-10-01. Neutron-induced fission reaction studies with minor actinides using a double Frisch grid fission detector. https://arxiv.org/abs/2310.00779

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development of an Extensible Unified Control System Using the STARS Framework and Common Commands for Detector Control

A zooming optical system comprising two Fresnel zone plates (FZPs) was developed and installed at the AR-NE1A beamline of the Photon Factory, High Energy Accelerator Research Organization (KEK), Japan. To ensure reliable and versatile operation, we implemented a dedicated control architecture based on the Simple Transmission and Retrieval System (STARS) framework and the newly proposed STARS Common Commands for Detector Control (CCDC)---a data-acquisition (DAQ) state model and command set designed specifically for detector control. The system serves both as a practical control system for the zooming optics and as a demonstration of modular extensibility using STARS and detector interoperability through CCDC. The system has been commissioned, and its performance has been verified at the AR-NE1A beamline. The architecture enables flexible configuration of optical components and provides a unified interface for both routine operation and advanced experimental protocols.

physics.ins-det

Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors

Experimental TCAD calibration is essential for predictive technology modeling of emerging oxide semiconductor transistors. However, it remains time-consuming and expert dependent because of model ambiguity. Multiple physical models and parameter sets can reproduce the same measured transfer characteristics, while local fitting alone cannot uniquely identify the underlying device physics. We present the first demonstration of an agentic TCAD calibration workflow for a fabricated bottom-gate In--W--O (BG-IWO) transistor. Starting from the measured transfer curve and device information, the workflow uses measurement--TCAD residuals and local sensitivity tests to select bounded parameter corrections or evaluate additional physical models, and accept only updates that improve device metrics. The LLM agent orchestrates the workflow, while Sentaurus governs the device physics. For the 2\%-W reference device, five agent-suggested updates yield a fixed calibrated model, reducing the multi-metric device objective $J$ by 14.3$\times$. Maximum $V_{\mathrm{th}}$/$I_{\mathrm{on}}$ errors are 36.1~mV/0.022 decade for varying-drain-bias tests and 46.2~mV/0.062 decade for varying-channel-length tests, demonstrating model transferability across bias and geometry rather than a local parameter fit. W-composition tests provide process-sensitive insight. This agentic workflow provides a faster route to model development for emerging device technologies.

physics.ins-det

Birefringence of AlGaAs/GaAs Coatings under Above-Band-Gap Illumination, GR Noise and Photo-Optic Transfer Function

AlGaAs/GaAs coatings are being considered as coating candidates for gravitational-wave detectors. In this paper we investigate the birefringence properties of this crystalline semiconductor material by modulating the optical illumination on the mirror coating and monitoring the induced birefringence. While the measured low-frequency birefringence values align with previous studies, we observed a frequency-dependent behavior in the illumination-to-birefringence coupling, characterized by a pole increasing with illumination intensity and a gain at zero frequency (DC gain) decreasing with illumination intensity. We developed a generic theoretical model based on a master equation to characterize the measurement results by considering photon-induced electric fields and electro-optic effects. This model can fit the frequency and intensity dependencies of the induced birefringence. Additionally, this model predicts a generation-recombination noise (GR noise) will be observable in the coating birefringence. While the presented measurement cannot predict the exact level of GR noise, for the frequency band and spot sizes relevant for gravitational-wave detectors we expect GR noise to be white below the pole frequency, scale with power the same way laser shot noise does, and for fixed power be independent of spot size.

physics.ins-det