Search arXivSearch

arXiv · 2310.11456

Innovative NiAl Electrodes for Long-Term, Intermediate High-Temperature SAW Sensing Applications Using LiNbO$_3$ Substrates

Abstract

Wireless SAW reflective delay line (R-DL) technology is very powerful to carry out remote measurements of various parameters under harsh environments, while enabling the identification of a given sensor among several of them. However, R-DL technology is currently limited to 350$^\circ$C for long-term applications, likely because of aluminium electrodes oxidation and/or congruent lithium niobate segregation process. In this study, an innovative alloy, namely NiAl, is investigated as an alternative to Al to make R-DLs able to withstand high temperatures up to 500$^\circ$C on the long term. Indeed, NiAl gathers, in the bulk state, all the necessary properties (fairly low electrical resistivity and density, high melting temperature and resistance to oxidation). The study also examines the extent of the congruent LiNbO$_3$ segregation process, to determine its impact on the NiAl/LiNbO$_3$ R-DLs performances. The obtained results are very promising. NiAl electrodes self-passivate during the first 50h of annealing at 500$^\circ$C: 20 nm-thick Al$_2$O$_3$ layers form at the surface and in between the electrodes and the substrate, protecting the remaining NiAl layer from further oxidation. Besides, the segregation process occurs mainly in the same time. It is located in the first 150-200 nm of the substrate. Both phenomena have no significant impact on the performance of NiAl/LiNbO$_3$ R-DLs working at 433 MHz. Continuous in-situ electrical monitoring of such devices shows a standard deviation of the operating frequency of only 1.04 ppm during an annealing process of 250h at 500$^\circ$C. Moreover, the time-resolved S11 response of the device at the end of this treatment is not degraded at all. Thus, 433 MHz NiAl/LiNbO$_3$ R-DL sensors can operate with high fidelity for at least 10 days at 500$^\circ$C under air atmosphere, and there are strong signs that their lifetime is actually much longer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jordan Maufay, Baptiste Paulmier, Mélanie Emo, Ulrich Youbi, Esther Mbina, Thierry Aubert, Ninel Kokanyan, Sami Hage-Ali, Michel Vilasi, Omar Elmazria. 2023-09-12. Innovative NiAl Electrodes for Long-Term, Intermediate High-Temperature SAW Sensing Applications Using LiNbO$_3$ Substrates. https://doi.org/10.1109/jsen.2023.3289008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det