Search arXivSearch

arXiv · 2311.03888

Impact of imperfect measurements on multi-party quantum key distribution

Abstract

The imperfection of measurements in real-world scenarios can compromise the performance of device-independent quantum key distribution (DIQKD) protocols. In this paper, we focus on a specific DIQKD protocol that relies on the violation of the Svetlichny's inequality (SI), considering an eavesdropper utilizing the convex combination attack. Our analysis covers both the three-party DIQKD case and the general $n$-party scenario. Our main result is the relationship between the measurement accuracy and the extractable secret-key rate in all multi-party scenarios. The result demonstrates that as measurement accuracy improves, the extractable secret-key rate approaches $1$, reaching its maximum value when the measurement accuracy is perfect. We reveal that achieving positive extractable secret-key rates requires a threshold measurement accuracy that is consistently higher than the critical measurement accuracy necessary to violate the SI. We depict these thresholds for $n$-party scenarios ranging from $n=3$ to $n=10$, demonstrating that as the number of parties ($n$) increases, both thresholds exhibit a rapid and monotonic convergence towards unity. Furthermore, we consider a scenario involving a non-maximally entangled state with imperfect measurements, where the emission of the initial GHZ state undergoes noise during transmission, resulting in a Werner state. The study further quantifies and demonstrates the relationship between the extractable secret-key rate, the visibility of the Werner state, and the measurement accuracy, specifically emphasizing the three-party scenario. This study aims to illuminate the influence of imperfect measurement accuracy on the security and performance of multi-party DIQKD protocols. The results emphasize the importance of high measurement accuracy in achieving positive secret-key rates and maintaining the violation of the SI.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yang Xiang. 2023-11-07. Impact of imperfect measurements on multi-party quantum key distribution. https://doi.org/10.1016/j.rinp.2023.107051

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph