Search arXivSearch

arXiv · 2311.12655

Hand-Eye Calibration

Abstract

Whenever a sensor is mounted on a robot hand it is important to know the relationship between the sensor and the hand. The problem of determining this relationship is referred to as hand-eye calibration, which is important in at least two types of tasks: (i) map sensor centered measurements into the robot workspace and (ii) allow the robot to precisely move the sensor. In the past some solutions were proposed in the particular case of a camera. With almost no exception, all existing solutions attempt to solve the homogeneous matrix equation AX=XB. First we show that there are two possible formulations of the hand-eye calibration problem. One formulation is the classical one that we just mentioned. A second formulation takes the form of the following homogeneous matrix equation: MY=M'YB. The advantage of the latter is that the extrinsic and intrinsic camera parameters need not be made explicit. Indeed, this formulation directly uses the 3 by 4 perspective matrices (M and M') associated with two positions of the camera. Moreover, this formulation together with the classical one cover a wider range of camera-based sensors to be calibrated with respect to the robot hand. Second, we develop a common mathematical framework to solve for the hand-eye calibration problem using either of the two formulations. We present two methods, (i) a rotation then translation and (ii) a non-linear solver for rotation and translation. Third, we perform a stability analysis both for our two methods and for the classical linear method of Tsai and Lenz (1989). In the light of this comparison, the non-linear optimization method, that solves for rotation and translation simultaneously, seems to be the most robust one with respect to noise and to measurement errors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Radu Horaud, Fadi Dornaika. 2023-11-22. Hand-Eye Calibration. https://doi.org/10.1177/027836499501400301

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

J-PARSE: Jacobian-based Projection Algorithm for Resolving Singularities Effectively in Inverse Kinematic Control of Serial Manipulators

J-PARSE is an algorithm for smooth first-order inverse kinematic control of a serial manipulator near kinematic singularities. The commanded end-effector velocity is interpreted component-wise, according to the available mobility in each dimension of the task space. First, a substitute ''Safety'' Jacobian matrix is created, keeping the aspect ratio of the manipulability ellipsoid above a threshold value. The desired velocity is then projected onto non-singular and singular directions, and the latter projection scaled down by a factor informed by the altered mobility. A right-inverse of the non-singular Safety Jacobian is applied to the modified command. In the absence of joint limits and collisions, this ensures safe transition into and out of low-mobility configurations, guaranteeing locally stable reaching behavior towards target poses within, on the boundary of, and outside the workspace. The behavior is further guaranteed to be locally asymptotically stable if the starting and target configurations are not exactly singular, even if they are nearly singular. Velocity control with J-PARSE is benchmarked against approaches from the literature, illustrating its use of a single tuning parameter to simultaneously achieve high reaching accuracy and stable behavior. Applications in teleoperation, servoing, and learning are demonstrated. Videos and code are available at https://jparse-manip.github.io/.

cs.RO

NeMo-map: Neural Implicit Flow Fields for Spatio-Temporal Motion Mapping

Safe and efficient robot operation in complex human environments can benefit from good models of site-specific motion patterns. Maps of Dynamics (MoDs) provide such models by encoding statistical motion patterns in a map, but existing representations use discrete spatial sampling and typically require costly offline construction. We propose a continuous spatio-temporal MoD representation based on implicit neural functions that directly map coordinates to the parameters of a Semi-Wrapped Gaussian Mixture Model. This removes the need for discretization and imputation for unevenly sampled regions, enabling smooth generalization across both space and time. Evaluated on two public datasets with real-world people tracking data, our method achieves better accuracy of motion representation and smoother velocity distributions in sparse regions while still being computationally efficient, compared to available baselines. The proposed approach demonstrates a powerful and efficient way of modeling complex human motion patterns and high performance in the trajectory prediction downstream task. The code is publicly available at https://github.com/test-bai-cpu/nemo-map.

cs.RO

Spatiotemporal Calibration of Doppler Velocity Logs for Underwater Robots

The calibration of extrinsic parameters and clock offsets between sensors for high-accuracy performance in underwater SLAM systems remains insufficiently explored. Existing methods for Doppler Velocity Log (DVL) calibration are either constrained to specific sensor configurations or rely on oversimplified assumptions, and none jointly estimate translational extrinsics and time offsets. We propose a Unified Iterative Calibration (UIC) framework for general DVL sensor setups, formulated as a Maximum A Posteriori (MAP) estimation with a Gaussian Process (GP) motion prior for high-fidelity motion interpolation. UIC alternates between efficient GP-based motion state updates and gradient-based calibration variable updates, supported by a provably statistically consistent sequential initialization scheme. The proposed UIC can be applied to IMU, cameras and other modalities as co-sensors. We release an open-source DVL-camera calibration toolbox. Beyond underwater applications, several aspects of UIC-such as the integration of GP priors for MAP-based calibration and the design of provably reliable initialization procedures-are broadly applicable to other multi-sensor calibration problems. Finally, simulations and real-world tests validate our approach.

cs.RO