Search arXivSearch

arXiv · 2311.15389

A concept of a para-hydrogen-based cold neutron source for simultaneous high flux and high brightness

Abstract

A novel cold neutron source (CNS) employing chessboard or staircase assemblies of high-aspect ratio rectangular (HARR) para-hydrogen (p-H2) moderators is proposed. It is demonstrated that this design can generate neutron beams with higher intensity and brightness, up to 2.5 times more than any p-H2 based CNS with an equal cold neutron beam cross-section made of a single moderator (flat or voluminous). Two limiting factors for this gain are identified: the limited volume of the high-density thermal neutron region surrounding the reactor core or spallation target imposing constraints on the total length of the moderator assembly and the finite width of moderator walls. Additional factors affecting gain can be revealed by dedicated Monte Carlo simulations of the moderator-reflector assembly, which can only be conducted for a particular neutron source and are beyond the scope of this general study. Moreover, the relatively large length of moderator assemblies makes their application for short pulse neutron sources very problematic. Analytic approach for calculating the brightness of p-H2 moderators is introduced. Because brightness gain originates from a near-the-surface effect resulting from the prevailing single collision process, HARR CMs offer a significant increase, up to a factor of 10, in cold neutron brightness. The obtained results are in excellent agreement with MCNP calculations. The concept of 'low-dimensionality' (low-d) in moderators is explored: achieving a substantial increase in brightness necessitates CMs to be low-d both geometrically (HARR) and physically, requiring the moderator's smallest dimension to be smaller than the mean free path for thermal neutrons. This explains why additional compression of the CM along the longest direction, effectively giving it a tube-like shape, does not leads to a significant brightness increase comparable to the flattening of CM.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alexander Ioffe, Petr Konik, Konstantin Batkov. 2024-10-04. A concept of a para-hydrogen-based cold neutron source for simultaneous high flux and high brightness. https://arxiv.org/abs/2311.15389

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det