Search arXivSearch

arXiv · 2312.02888

Compensation of front-end and modulation delays in phase and ranging measurements for time-delay interferometry

Abstract

In the context of the Laser Interferometer Space Antenna (LISA), the laser subsystems exhibit frequency fluctuations that introduce significant levels of noise into the measurements, surpassing the gravitational wave signal by several orders of magnitude. Mitigation is achieved via time-shifting individual measurements in a data processing step known as time-delay interferometry (TDI). The suppression performance of TDI relies on accurate knowledge and consideration of the delays experienced by the interfering lasers. While considerable efforts have been dedicated to the accurate determination of inter-spacecraft ranging delays, the sources for onboard delays have been either neglected or assumed to be known. Contrary to these assumptions, analog delays of the phasemeter front end and the laser modulator are not only large but also prone to change with temperature and heterodyne frequency. This motivates our proposal for a novel method enabling a calibration of these delays on-ground and in-space, based on minimal functional additions to the receiver architecture. Specifically, we establish a set of calibration measurements and elucidate how these measurements are utilized in data processing, leading to the mitigation of the delays in the TDI Michelson variables. Following a performance analysis of the calibration measurements, proposed calibration scheme is assessed through numerical simulations. We find that in the absence of the calibration scheme, the assumed drifts of the analog delays increase residual laser noise at high frequencies of the LISA measurement band. A single, on-ground calibration of the analog delays leads to an improvement by roughly one order of magnitude, while re-calibration in space may improve performance by yet another order of magnitude. Towards lower frequencies, ranging error is always found to be the limiting factor for which countermeasures are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Philipp Euringer, Niklas Houba, Gerald Hechenblaikner, Oliver Mandel, Francis Soualle, Walter Fichter. 2024-01-12. Compensation of front-end and modulation delays in phase and ranging measurements for time-delay interferometry. https://arxiv.org/abs/2312.02888

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det