Deep mouse brain two-photon near-infrared fluorescence imaging using a superconducting nanowire single-photon detector array

Abstract

Two-photon microscopy (2PM) has become an important tool in biology to study the structure and function of intact tissues in-vivo. However, adult mammalian tissues such as the mouse brain are highly scattering, thereby putting fundamental limits on the achievable imaging depth, which typically resides around 600-800um. In principle, shifting both the excitation as well as (fluorescence) emission light to the shortwave near-infrared (SWIR, 1000-1700 nm) region promises substantially deeper imaging in 2PM, yet has proven challenging in the past due to the limited availability of detectors and probes in this wavelength region. To overcome these limitations and fully capitalize on the SWIR region, in this work we introduce a novel array of superconducting nanowire single-photon detectors (SNSPDs) and associated custom detection electronics for the use in near-infrared 2PM. The SNSPD array exhibits high efficiency and dynamic range, as well as low dark-count rates over a wide wavelength range. Additionally, the electronics and software permit seamless integration into typical 2PM systems. Together with a fluorescent dye emitting at 1105 nm, we report imaging depth of > 1.1mm in the in-vivo mouse brain, limited only by available labeling density and laser power. Our work further establishes SWIR 2PM approaches and SNSPDs as promising technologies for deep tissue biological imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Amr Tamimi, Martin Caldarola, Sebastian Hambura, Juan C. Boffi, Niels Noordzij, Johannes W. N. Los, Antonio Guardiani, Hugo Kooiman, Ling Wang, Christian Kieser, Florian Braun, Andreas Fognini, Robert Prevedel. 2023-12-21. Deep mouse brain two-photon near-infrared fluorescence imaging using a superconducting nanowire single-photon detector array. https://arxiv.org/abs/2312.14042

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Paraxial diffusion-field retrieval. II. Fokker-Planck generalization of the transport-of-intensity equation

The transport-of-intensity equation (TIE), namely the continuity equation associated with a coherent paraxial optical wavefield, is widely used for phase retrieval. It is a second-order partial differential equation which may be solved for the phase of a coherent paraxial field such as a monochromatic scalar optical beam, given the intensity and longitudinal intensity derivative in a plane perpendicular to the optical axis. We show how the coherent flow associated with the TIE may be augmented by a diffusive flow associated with a scalar or tensor diffusion field. Such diffusive flow can arise via scattering from unresolved spatially random microstructure in an illuminated sample, blurring effects of an extended chaotic source that illuminates the sample, the resolution-reducing effect of shot noise in detected intensity images of the sample, and the sharpening effect (negative diffusion) associated with scattering from sharp sample edges. Augmenting the TIE's modeling of coherent flow with a diffuse-flow channel leads to a Fokker-Planck extension to this equation. Two different augmentations are obtained, using several complementary derivations. The inverse problems of phase retrieval and diffusion-field retrieval are then considered, for defocus-based imaging and mask-based imaging. When symmetric overfocus and underfocus images are used for phase retrieval, the diffusive term drops out and our Fokker-Planck formalism implies that any ensuing TIE-based phase-retrieval method needs no modification in light of our formalism. However, the same focal-series dataset---typically an infocus image, a weakly overfocused image, and a weakly underfocused image---may also be employed to access the additional channel of information associated with the Fokker-Planck diffusion field. Our formalism is applicable to visible light, x-ray, electron, and neutron imaging.

physics.optics

Robust multichannel bulk transport in a time-reversal-invariant insulator-free photonic waveguide array

Ultracompact cladding-free waveguide arrays with zero inter-channel spacing and negligible crosstalk open a new avenue for high-density integrated photonic circuits. However, existing cladding-free waveguide arrays typically rely on conventional trivial bulk modes, making them highly susceptible to scattering losses at sharp bends or in the presence of obstacles and defects. To overcome this limitation, we theoretically propose and experimentally demonstrate a robust, crosstalk-free, and cladding-free photonic waveguide array based on chiral anomaly bulk states (CABSs) in photonic crystals. By interfacing distinct Dirac photonic crystals that host Dirac cones at different high-symmetry points (Γ and K) in the Brillouin zone and carefully engineering the boundary conditions, the boundary-induced CABSs in adjacent channels become effectively decoupled due to a large momentum separation, thereby eliminating inter-channel crosstalk. More importantly, we experimentally demonstrate that these crosstalk-free CABSs are robust to perturbations, including metallic obstacles, air defects, and sharp bends. We further extend the CABS-based waveguide array to two dimensions and demonstrate a cladding-free triangular resonator and a crosstalk-free waveguide crossing, both of which are previously unattainable. Our work establishes a new design paradigm for cladding-free, crosstalk-free, and ultracompact topological photonic devices, paving the way for robust, highly integrated photonic circuits.

physics.optics

A conformally-Euclidean Line Element for evaluating color differences

Starting from our previously proposed line element and considering more ``surface color'' datasets, we derive a simplified version which matches experimental datasets equally well and resulted into a conformally-Euclidean line element, which is conceptually much simpler than any existing color difference metrics. The color difference is written as an Euclidean difference multiplied with a simple factor which depends on the luminance only. In a subspace with constant luminance, as considered by MacAdam, this factor becomes constant and the subspace is flat. The same holds for sufficiently large luminances. Based on this LE we derive perceptual coordinates $\left(A,l_{c},s_{c}\right)$ very similar to the CIELab $\left(L^{*},a^{*},b^{*}\right)$.

physics.optics