arXiv · 2401.11875
Design and characterisation of an antiproton deceleration beamline for the PUMA experiment
Abstract
We report on the design and characterization of an antiproton deceleration beamline, based on a pulsed drift tube, for the PUMA experiment at the Antimatter Factory at CERN. The design has been tailored to high-voltage (100 kV) and ultra-high vacuum (below $10^{-10}$ mbar) conditions. A first operation achieved decelerating antiprotons from an initial energy of 100 keV down to ($3898\pm 3$) eV, marking the initial stage in trapping antiprotons for the PUMA experiment. Employing a high-voltage ramping scheme, the pressure remains below $2\cdot 10^{-10}$ mbar upstream of the pulsed drift tube for 75% of the cycle time. The beamline reached a transmission of ($55 \pm 3$)% for antiprotons decelerated to 4 keV. The beam is focused on a position sensitive detector to a spot with horizontal and vertical standard deviations of ${\sigma}_\mathrm{horiz}$ = ($3.0 \pm 0.1$) mm and ${\sigma}_\mathrm{vert}$ = ($3.8 \pm 0.2$) mm, respectively. This spot size is within the acceptance of the PUMA Penning trap.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J. Fischer, A. Schmidt, N. Azaryan, F. Butin, J. Ferreira Somoza, A. Husson, C. Klink, A. Obertelli, M. Schlaich, A. Sinturel, N. Thaus, F. Wienholtz. 2024-01-22. Design and characterisation of an antiproton deceleration beamline for the PUMA experiment. https://doi.org/10.1016/j.nimb.2024.165318
Cite the original work for its findings. Save a collection to share your selection of sources.