Search arXivSearch

arXiv · 2403.03534

Characterization of the low electric field and zero-temperature two-level-system loss in hydrogenated amorphous silicon

Abstract

Two-level systems (TLS) are an important, if not dominant, source of loss and noise for superconducting resonators such as those used in kinetic inductance detectors and some quantum information science platforms. They are similarly important for loss in photolithographically fabricated superconducting mm-wave/THz transmission lines. For both lumped-element and transmission-line structures, native amorphous surface oxide films are typically the sites of such TLS in non-microstripline geometries, while loss in the (usually amorphous) dielectric film itself usually dominates in microstriplines. We report here on the demonstration of low TLS loss at GHz frequencies in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition in superconducting lumped-element resonators using parallel-plate capacitors (PPCs). The values we obtain from two recipes in different deposition machines, 7$\,\times\,10^{-6}$ and 12$\,\times\,10^{-6}$, improve on the best achieved in the literature by a factor of 2--4 for a-Si:H and are comparable to recent measurements of amorphous germanium. Moreover, we have taken care to extract the true zero-temperature, low-field loss tangent of these films, accounting for temperature and field saturation effects that can yield misleading results. Such robustly fabricated and characterized films render the use of PPCs with deposited amorphous films a viable architecture for superconducting resonators, and they also promise extremely low loss and high quality factor for photolithographically fabricated superconducting mm-wave/THz transmission lines used in planar antennas and resonant filters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fabien Defrance, Andrew D. Beyer, Shibo Shu, Jack Sayers, Sunil R. Golwala. 2024-03-06. Characterization of the low electric field and zero-temperature two-level-system loss in hydrogenated amorphous silicon. https://doi.org/10.1103/physrevmaterials.8.035602

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det