Search arXivSearch

arXiv · 2403.04498

PCH-EM: A solution to information loss in the photon transfer method

Abstract

Working from a Poisson-Gaussian noise model, a multi-sample extension of the Photon Counting Histogram Expectation Maximization (PCH-EM) algorithm is derived as a general-purpose alternative to the Photon Transfer (PT) method. This algorithm is derived from the same model, requires the same experimental data, and estimates the same sensor performance parameters as the time-tested PT method, all while obtaining lower uncertainty estimates. It is shown that as read noise becomes large, multiple data samples are necessary to capture enough information about the parameters of a device under test, justifying the need for a multi-sample extension. An estimation procedure is devised consisting of initial PT characterization followed by repeated iteration of PCH-EM to demonstrate the improvement in estimate uncertainty achievable with PCH-EM; particularly in the regime of Deep Sub-Electron Read Noise (DSERN). A statistical argument based on the information theoretic concept of sufficiency is formulated to explain how PT data reduction procedures discard information contained in raw sensor data, thus explaining why the proposed algorithm is able to obtain lower uncertainty estimates of key sensor performance parameters such as read noise and conversion gain. Experimental data captured from a CMOS quanta image sensor with DSERN is then used to demonstrate the algorithm's usage and validate the underlying theory and statistical model. In support of the reproducible research effort, the code associated with this work can be obtained on the MathWorks File Exchange (Hendrickson et al., 2024).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aaron J. Hendrickson, David P. Haefner, Stanley H. Chan, Nicholas R. Shade, Eric R. Fossum. 2024-03-07. PCH-EM: A solution to information loss in the photon transfer method. https://arxiv.org/abs/2403.04498

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det