Abstract

Many countries have commenced a transition from fossil fuel-based electricity generation systems to sustainable systems based on wind and solar generation. It is often noted that the least cost approach would involve a massive scale-up in the building of variable renewables, supported by battery storage and gas peaking plants. The required backup should be firm-dispatchable generation rather than peaking power. The wind and solar generation aspects for this system are clearly defined and understood, however, the term firm-dispatchable power is not defined and the specific requirements are poorly understood. This study seeks to define firm-dispatchable power in this context and its requirement in the sustainable generation system. The study compares 100% renewable generation scenarios from South Africa, Texas, and the UK to demonstrate the requirement for this firm-dispatchable generation. The results indicate that firm-dispatchable generation must be available to replace the renewable generation completely. The required installed capacity for this firm-dispatchable generation does not vary with the distinct demand profiles of the different locations or their comparative renewable generation profiles. It also does not change significantly with the use of energy storage. The usage for this firm-dispatchable generation will vary due to the comparative economics of its use, but the requirement for its installation does not change.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephen R. Clark, Craig McGregor. 2024-03-16. Firm-Dispatchable Power and its Requirement in a Power System based on Variable Generation. https://arxiv.org/abs/2403.10869

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Safe learning-based control via function-based uncertainty quantification

Uncertainty quantification is essential when deploying learning-based control methods in safety-critical systems. This is commonly realized by constructing uncertainty tubes that enclose the unknown function of interest, e.g., the reward and constraint functions or the underlying dynamics model, with high probability. However, existing approaches for uncertainty quantification typically rely on restrictive assumptions that encode smoothness properties of the unknown function, such as a known norm in a function space. Moreover, these methods usually struggle with discontinuities. In this paper, we model the unknown function as a random function from which independent and identically distributed realizations can be generated. We then construct uncertainty tubes via the scenario approach that hold with high probability. Our uncertainty tubes rely solely on sampled realizations and can therefore accommodate discontinuities represented by the sampling model. We integrate these uncertainty tubes into a safe Bayesian optimization algorithm with which we safely tune control parameters on a real Furuta pendulum.

eess.SY

Enhanced ShockBurst for Ultra Low-Power On-Demand Sensing

On-demand sensing requires battery-powered Internet-of-Things (IoT) and implantable medical devices to remain in deep sleep and activate wireless communication only when data transmission is required. In such systems, battery lifetime depends strongly on radio active time. This work investigates how communication architecture and physical layer (PHY) configuration influence radio active time by comparing connection-oriented Bluetooth Low Energy (BLE) with connectionless Enhanced ShockBurst (ESB) on identical BLE-compatible hardware. Under identical 2 Mbps PHY configurations, ESB reduces wake-up latency and energy consumption to approximately one-twentieth of BLE by eliminating connection establishment and maintenance overhead. Increasing the ESB PHY rate from 2 to 4 Mbps further shortens packet airtime by approximately 52% and reduces transmission energy by approximately 43%. Finally, a first-in, first-out (FIFO)-triggered implantable loop recorder prototype demonstrates that jointly optimizing communication architecture, PHY configuration, and buffered transmission enables sleep-wake operation and reduces total system power consumption by approximately 60% compared with conventional BLE operation. These results identify minimizing radio active time as a key design principle for ultra-low-power on-demand sensing and provide practical guidance for battery-powered sensing systems.

eess.SY

Receding Horizon Multi-Agent Deceptive Path Planner

Deceptive path planning enables autonomous agents to obscure their true goals from observers by deviating from an expected optimal path. Prior work largely solves full-horizon, end-to-end optimization for single agents, which is expensive to recompute online and difficult to scale or adapt en route. We propose a unified framework for deceptive path planning using a Boltzmann distribution, computing over short-horizon candidate trajectories within a receding-horizon loop. By param- By iterating a user-defined cost that captures deception, resources, and smoothness, and optionally includes coupling terms between agents, the framework yields stochastic policies that balance the tradeoff between optimal paths and deceptive deviation. Policies are updated locally and do not require training. The level of deception and adherence to constraints can be dynamically tuned, enabling online adaptation to changes in goals and constraints such as obstacles. This step-by-step tuning opens the door to new forms of dynamic deception. Simulation studies demonstrate the flexibility of our approach, maintaining deception while adapting to environmental and constraint updates, avoiding the recomputation required by full-horizon methods, and supporting intuitive tuning via a small set of parameters

eess.SY