Search arXivSearch

arXiv · 2404.06377

Experimental study of second sound quench detection for superconducting cavities

Abstract

Superconducting RF cavities are used in particle accelerators to provide energy to the particle beam. Such cavities are mostly fabricated in niobium and often operated in superfluid helium. One of their limits of operation is the appearance of a local quench, initiated by a local field enhancement due to a defect, which leads to a normal conducting transition of the cavity. Localizing the quench area can be achieved with temperature mapping systems. Another method is the use of second sound wave propagation in superfluid helium. Measuring the time of propagation of these waves from quench location to special sensors, called Oscillating Superleak Transducers (OSTs), and using their well-known velocity should allow trilateration. However, most of experimental measurements on cavities show "premature signals", i.e. the second sound signals arrive earlier on the OSTs than expected. This paper presents several quench experiments on cavities equipped with OSTs and temperature mapping quench detection systems. Two hypotheses can explain the observed premature signals. The first one assesses faster propagation in helium. An experimental setup has been developed for testing this hypothesis, where second sound is created by a localized heater in a controlled environment up to 4.3 kW/cm2 and 2.8 J. Premature signals could not be verified in this setup. A second hypothesis based on a simple model including several processes in niobium and second sound propagation in helium is discussed. The model improves significantly the prediction of the times of arrival of the second sound waves. The overall study shows that the processes in niobium play a prominent role in the second sound detection for superconducting cavities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Juliette Plouin, Bertrand Baudouy, Aurélien Four, Jean-Pierre Charrier, Luc Maurice, Jorge Novo, Benedikt Peters, Kitty Liao. 2024-04-09. Experimental study of second sound quench detection for superconducting cavities. https://doi.org/10.1103/physrevaccelbeams.22.083202

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-power attosecond X-ray free-electron lasers: physics and design strategy

Attosecond pulses from X-ray free-electron laser (XFEL) have opened new opportunities for probing ultrafast electronic dynamics on the Angstrom--attosecond spatiotemporal scale. Most attosecond XFEL concepts rely on generating an ultrashort high-current spike through either external laser modulation or accelerator-based beam manipulation. Despite their different implementations, these approaches share the same essential physics, namely that the XFEL amplification is confined to a short effective lasing window within the electron beam. However, existing studies are often scheme-specific and do not yet provide a unified quantitative picture of how fundamental electron-beam properties constrain high-power attosecond performance. In this work, we investigate the general physics and scheme-independent requirements for generating high-power attosecond X-ray pulses from a short current spike. From the perspective of post-saturation superradiant evolution, we show that the effective lasing length of the electron beam governs both the attainable peak power and the pulse duration. We further examine the distinct roles of slice energy spread, slice emittance, energy chirp, undulator tapering, and transverse beam tilt. Our results reveal the trade-off between peak power, pulse shortening, and single-spike probability, and provide facility-independent guidelines for optimizing electron-beam phase-space manipulation toward terawatt-class attosecond XFEL operation.

physics.acc-ph

Bayesian Optimization of The Relativistic Heavy Ion Collider Luminosity via $s^*$ Control

Maximizing luminosity at the interaction point (IP) requires the collision location $s_{IP}$ to coincide with the longitudinal position of the minimum beta function, $s^$. Accurate optics measurements and control of $s^$ are therefore essential for luminosity optimization. At the Relativistic Heavy Ion Collider (RHIC), average horizontal beta-beat measurements between operating IPs are approximately $20%$, with significant variation in measured $s^*$. Precise control of the beam waist position $s^$ is particularly challenging for modern high-energy colliders with short bunch lengths and large crossing angles. We present an online Bayesian optimization (BO) application using the GPTune framework to optimize sPHENIX luminosity through $s^$ control at RHIC. GPTune was first validated at the RHIC Electron Beam Ion Source (EBIS), where it achieved up to a $70%$ increase in beam intensity over the baseline, although experienced operators could reach similar performance with longer manual tuning. The framework was subsequently deployed during sPHENIX operations. Using an intensity-normalized Zero-Degree Calorimeter (ZDC) signal as the optimization objective, due to the unavailability of the live sPHENIX MVTX signal, GPTune identified local luminosity maxima, recovered from intentionally degraded $s^$ configurations, and revealed residual horizontal and vertical waist offsets in the interaction region. These results demonstrate the robustness and efficiency of Bayesian optimization for real-time collider tuning under noisy, time-varying conditions. The $s^$ control methodology provides a promising tool for precision luminosity optimization and is particularly relevant to next-generation short-bunch colliders such as the Electron-Ion Collider (EIC).

physics.acc-ph

Ultralow Mean Transverse Energy and High Quantum Efficiency Cryogenic Bialkali Photocathode for MHz-Repetition-Rate Electron Sources

Simultaneously achieving high quantum efficiency (QE), ultralow mean transverse energy (MTE), and robust long-term operation under conditions relevant to continuous-wave (CW) X-ray free-electron lasers (XFELs) remains a central challenge for semiconductor photocathodes. This challenge arises from the trade-off between QE and MTE, as well as the difficulty of maintaining stable operation in high-field CW electron guns. Here we demonstrate a cryogenic K2CsSb photocathode that simultaneously achieves high QE, ultralow MTE, and robust long-term operation in a CW gun under XFEL-relevant operating conditions. Under cryogenic operation, the photocathode achieves an MTE of 50 meV while sustaining a QE of 5.4%. Milliampere-level CW current, including operation at 5 mA, was demonstrated together with an approximately 20-day operational history. The observations are consistent with improved carrier survival and/or surface escape in photocathodes prepared using the optimized recipe. These results show that the practical QE-MTE trade-off can be substantially mitigated in cryogenic bialkali photocathodes and provide a practical pathway toward high-brightness electron sources for CW XFELs and energy-recovery linacs.

physics.acc-ph