Search arXivSearch

arXiv · 2404.10197

Novel Method to Estimate Kinetic Microparameters from Dynamic Whole-Body Imaging in Regular-Axial Field-of-View PET Scanners

Abstract

For whole-body (WB) kinetic modeling based on a typical PET scanner, a multi-pass multi-bed scanning protocol is necessary given the limited axial field-of-view. Such a protocol introduces loss of early-dynamics in time-activity curves (TACs) and sparsity in TAC measurements, inducing uncertainty in parameter estimation when using least-squares estimation (LSE) (i.e., common standard) especially for kinetic microparameters. We present a method to reliably estimate microparameters, enabling accurate parametric imaging, on regular-axial field-of-view PET scanners. Our method, denoted parameter combination-driven estimation (PCDE), relies on generation of reference truth TAC database, and subsequently selecting, the best parameter combination as the one arriving at TAC with highest total similarity score (TSS), focusing on general image quality, overall visibility, and tumor detectability metrics. Our technique has two distinctive characteristics: 1) improved probability of having one-on-one mapping between early and late dynamics in TACs (the former missing from typical protocols), and 2) use of multiple aspects of TACs in selection of best fits. To evaluate our method against conventional LSE, we plotted tradeoff curves for noise and bias. In addition, the overall SNR and spatial noise were calculated and compared. Furthermore, CNR and TBR were also calculated. We also tested our proposed method on patient data (18F-DCFPyL PET scans) to further verify clinical applicability. Significantly improved general image quality performance was verified in microparametric images (e.g. noise-bias performance). The overall visibility and tumor detectability were also improved. Finally, for our patient studies, improved overall visibility and tumor detectability were demonstrated in micoparametric images, compared to use of conventional parameter estimation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kyung-Nam Lee, Arman Rahmim, Carlos Uribe. 2024-05-13. Novel Method to Estimate Kinetic Microparameters from Dynamic Whole-Body Imaging in Regular-Axial Field-of-View PET Scanners. https://arxiv.org/abs/2404.10197

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph