Temporal and dosimetric beam monitoring of individual pulses in FLASH Radiotherapy using Timepix3 pixelated detector placed out-of-field

Abstract

FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate and online monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods tailored for single-pulse detection. The goal of this work was to measure the delivered number of pulses, investigate temporal structure of individual pulses, and to develop a method for dose-per-pulse (DPP) monitoring based on secondary radiation particles produced in the experimental room. A 20 MeV electron beam generated from a linear accelerator (LINAC) was delivered to a water phantom. Ultra-high dose-per-pulse (UHDPP) electron beams were used with a dose per pulse ranging from 1 Gy to over 7 Gy. The pulse lengths ranged from 1.18 us to 2.88 us at a pulse rate frequency of 5 Hz. A semiconductor pixel detector Timepix3 (TPX3) was used to track direct interactions in the Silicon sensor created by single secondary particles. Measurements were performed in the air, while the detector was positioned out-of-field at a lateral distance of 200 cm parallel with the LINAC exit window. The dose deposited in the silicon was measured along with the pulse length and the nanostructure of the pulse. Simultaneously deposited energy and time of arrival of single particles were measured with a precision of 1.56 ns. The measured pulse count agreed with the delivered values. A linear response (R^2 = 0.999) was established between the delivered beam current and the measured dose at the detector position (orders of nGy). The difference between the average measured and average delivered pulse length was 0.003(30) us. This simple non-invasive method, exhibits no limitations on the delivered DPP within the range used during this investigation. It enhances the precision and real-time monitoring of FLASH treatment plans with nanosecond precision.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cristina Oancea, Katerina Sykorova, Jan Jakubek, Jiri Pivec, Felix Riemer, Steven Worm, Alexandra Bourgouin. 2024-04-21. Temporal and dosimetric beam monitoring of individual pulses in FLASH Radiotherapy using Timepix3 pixelated detector placed out-of-field. https://arxiv.org/abs/2404.13732

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph