Search arXivSearch

arXiv · 2404.15122

Life Cycle Assessment of the Athena X-ray Integral Field Unit

Abstract

The X-ray Integral Field Unit (X-IFU) is the high-resolution X-ray spectrometer to fly on board the Athena Space Observatory of the European Space Agency (ESA). It is being developed by an international Consortium led by France, involving twelve ESA member states, plus the United States. It is a cryogenic instrument, involving state of the art technology, such as micro-calorimeters, to be read out by low noise electronics. As the instrument was undergoing its system requirement review (in 2022), a life cycle assessment (LCA) was performed to estimate the environmental impacts associated with the development of the sub-systems that were under the responsibility of the X-IFU Consortium. The assessment included the supply, manufacturing and testing of sub systems, as well as involved logistics and manpower. We find that the most significant environmental impacts arise from testing activities, which is related to energy consumption in clean rooms, office work, which is related to energy consumption in office buildings, and instrument manufacturing, which is related to the use of mineral and metal resources. Furthermore, business travels is another area of concern, despite the policy to reduced flying adopted by the Consortium. As the instrument is now being redesigned to fit within the new boundaries set by ESA, the LCA will be updated, with a focus on the hot spots identified in the first iteration. The new configuration, consolidated in 2023, is significantly different from the previously studied version and is marked by an increase of the perimeter of responsibility for the Consortium. This will need to be folded in the updated LCA, keeping the ambition to reduce the environmental footprint of X-IFU, while complying with its stringent requirements in terms of performance and risk management.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Didier Barret, Vincent Albouys, Jürgen Knödlseder, Xavier Loizillon, Matteo D'Andrea, Florence Ardellier, Simon Bandler, Pieter Dieleman, Lionel Duband, Luc Dubbeldam, Claudio Macculi, Eduardo Medinaceli, Francois Pajot, Damien Prêle, Laurent Ravera, Tanguy Thibert, Isabel Vera Trallero, Natalie Webb. 2024-04-23. Life Cycle Assessment of the Athena X-ray Integral Field Unit. https://arxiv.org/abs/2404.15122

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Scale Contrastive Attention for Light-Curve Representation Learning

Current and next-generation time-domain surveys demand automated techniques capable of analyzing millions of light curves, observed in multiple filters, without relying on exhaustive human annotation or scarce spectroscopic follow-up. We present Astra-CLR, an attention-based, self-supervised contrastive learning framework which enables the representation of raw light curves into a highly discriminative latent space. Pre-trained on $\sim$2.1 million unlabeled Zwicky Transient Facility light curves, the framework utilizes partial light curves as input sequences to generate asymmetric, multi-scale temporal views (explicitly contrasting shorter sequences against longer ones) forcing the network to learn a robust "local-to-global" mapping strategy. Furthermore, we introduce a novel multi-view late fusion architecture that extends the model to efficiently handle longer light curves with larger numbers of observations while accommodating the different cadences associated with each filter. The discriminatory power of the resulting representations was evaluated by using them as input to a Multinomial Logistic Regression classifier, trained to identify 12 broad classes of variability. Final accuracy achieved $\sim 0.70$. When applying a label-efficient, partial top-layer fine-tuning strategy, the topological structure of the latent space is significantly refined, boosting results to $\sim$0.77. Astra-CLR is the first publicly available multi-filter time-series Transformer trained exclusively on real ZTF light curves. Results presented here demonstrate that it provides an ideal foundation for the development of end-to-end pipelines, taking into account color evolution and respecting the inhomogeneous nature of astronomical light curve sampling.

astro-ph.IM

Combining astrometry with pulsar timing: the first joint analysis of very low frequency gravitational waves

The pHz to sub-nHz GW regime remains largely unexplored but is crucial for mapping the early inspiral stage of SMBHBs and probing early-Universe physics. Astrometry and pulsar timing offer orthogonal and deeply complementary secular observables to investigate this frequency band. We aim to present the first joint data analysis combining real astrometric proper motions with binary pulsar timing, to search for and constrain continuous gravitational waves (CWs) sourced by SMBHBs in the ultra-low-frequency regime ($10^{-12} \le f_{GW} \le10^{-9} Hz$). We employ a Bayesian model selection and upper limit estimation framework to combine apparent proper motion displacements of $\sim 1.5 \times 10^6$ quasars from the Gaia CRF3 catalog with the line-of-sight orbital period derivatives ($\dot{P}_b$) of 11 high-precision binary pulsars. To prevent spurious detections, we heavily model instrumental and astrophysical systematics: we propagate the Galactic potential uncertainty for pulsars via Monte Carlo simulations and perform a Vector Spherical Harmonics (VSH) decomposition up to the octupole order (l=3) for quasars. We find no statistically significant evidence for a CWs signal in the joint analysis ($\ln B_{joint} = -0.42 \pm 0.03$). In the absence of detection, we set the tightest constraints to date on CW strain in the pHz band, yielding a 95% upper limit of $h_0\le6.4x10^{-11}$ at a reference frequency of $f_{ref} = 4 \times 10^{-10}$ Hz. The combined dataset achieves full sky coverage and improves single-dataset upper limits by 20%-30%. Combining orthogonal observables successfully breaks spatial degeneracies intrinsic to isolated searches. Furthermore, forecasts from inj.-rec. indicate that with the extended temporal baseline and reduced uncertainties of the upcoming Gaia DR4, this joint framework is poised to break the $h_0 < 10^{-11}$ upper limit barrier for sub-nHz CWs.

astro-ph.IM

Bayesian classification of astronomical spectra with class uncertainties

Context: We developed a probabilistic machine learning method with the aim of performing the O(10)-way classification of low- and high-resolution spectra of stellar and extragalactic targets for the upcoming 4MOST survey. In fulfilment of the survey requirements, this method should be able to express uncertainty in the input data as well as uncertainty introduced in its prediction. Aims: Four different methods are explored: (1) convolutional neural networks (CNNs), (2) the Dirichlet distribution, (3) Monte Carlo dropout (MCD), (4) Bayesian neural Networks (BNNs) + variational inference (VI). Training and validation was performed using labelled spectra from the SDSS database and a custom 4MOST mock dataset. All the methods were compared in terms of the same metrics: accuracy, area under the curve (AUC), expected calibration error (ECE), Shannon entropy, negative log-likelihood (NLL), Brier score, training time, and inference time. Methods: A CNN with simple architecture and about 20,000 parameters was trained to achieve classification accuracies of 91.5% on SDSS data and 92.8% on 4MOST mock data. The direct Dirichlet prediction and VI models tested provide uncertainties on class membership probabilities, but they confuse classes more often. The MCD on a CNN is found to be the most suitable; it boosts the point-estimate accuracies to 92.6% and 93.9%, while still providing fast training and sufficiently fast inference. Compared to a standard CNN, the method additionally provides well-calibrated uncertainties at marginal extra cost.

astro-ph.IM