Search arXivSearch

arXiv · 2405.12194

Histotripsy of blood clots within a hollow cylindrical transducer for aspiration thrombectomy applications

Abstract

Thrombolytic occlusions in stroke, pulmonary embolism and the peripheral vasculature are increasingly treated with aspiration, a catheter-based approach that employs suction to extract clots through a hollow catheter lumen. Unfortunately, aspiration is frequently unsuccessful in extracting more challenging clots, which can become corked in the distal tip. We hypothesize that clot extraction can be enhanced by using histotripsy to degrade the mechanical integrity of clot material within the lumen of a hollow cylindrical transducer which can be situated at the tip of an aspiration catheter. To demonstrate the feasibility of degrading clot material within the lumen of a hollow cylindrical transducer, the effect of pulsing schemes on lesion generation within clots was assessed using a retracted clot model. A radially polarized cylindrical transducer (2.5 mm and 3.3 mm for inner and outer diameter, 2.5 mm length, PZT) working at 6.1 MHz was used to degrade retracted porcine clots with pulse lengths of 10, 20, and 100 us, pulse repetition frequencies (PRF) of 100, 500, and 1000 Hz, using treatment times from 0.1 to 10 seconds (n = 5 clots per condition). 3D ultrasound scans and bisected optical examinations of treated clots confirmed the formation of liquified zones. Lesions could form within 0.1 seconds along the central axis of the transducer and then grow in diameter and length over time. The lesion volume was found to be highly dependent on the exposure scheme, with the largest lesion volume associated with the 10 us pulse length 1000 kHz PRF case. Collectively these results demonstrate the feasibility of degrading blood clots within hollow cylindrical transducers, which suggests their potential for enhancing aspiration based mechanical thrombectomy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Li Gong, Alex R. Wright, Kullervo Hynynen, David E. Goertz. 2024-05-20. Histotripsy of blood clots within a hollow cylindrical transducer for aspiration thrombectomy applications. https://arxiv.org/abs/2405.12194

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph