Search arXivSearch

arXiv · 2405.12457

A High Compression Ratio Channel Multiplexing Method for Micro-pattern Gaseous Detectors

Abstract

The demand for a large number of readout channels has been a limiting factor for the application of Micro-pattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further compounded by issues related to system integration, power consumption, and cost efficiency. To address these challenges, this study proposes two novel multiplexing methods based on Eulerian circuits. Mathematical calculations indicate that with $n$ electronics channels, up to $n \times (n-1)/2 - (n - 2)/2 + 1$ detector channels can be read out, where $n$ is even. Three types of multiplexing circuits were designed, implemented, and tested in combination with Micromegas detectors. Experimental results demonstrate that, for a multiplexing circuit with a factor of 8, the spatial resolution remains comparable to the direct readout method, while achieving a detection efficiency exceeding 94\%. For a circuit with a multiplexing factor of 16, although the spatial resolution shows a slight degradation, the detection efficiency remains above 93.6\%. These results demonstrate that the proposed multiplexing methods can significantly reduce the number of readout channels while maintaining an acceptable level of spatial resolution and detection efficiency. These findings highlight the potential of the proposed multiplexing techniques for applications in fields requiring high-resolution and cost-effective detector systems, such as cosmic-ray muon imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yu Wang, Shubin Liu, Hao Zhuang, Zhengwu Ding, Zhihang Yao, Changqing Feng, Zhiyong Zhang. 2025-05-21. A High Compression Ratio Channel Multiplexing Method for Micro-pattern Gaseous Detectors. https://arxiv.org/abs/2405.12457

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det