Abstract

Portable heart rate monitoring (HRM) systems based on electrocardiograms (ECGs) have become increasingly crucial for preventing lifestyle diseases. For such portable systems, minimizing power consumption and sampling rate is critical due to the substantial data generated during long-term ECG monitoring. The variable pulse-width finite rate of innovation (VPW-FRI) framework provides an effective solution for low-rate sampling and compression of ECG signals. We develop a time-based sub-Nyquist sampling and reconstruction method for ECG signals specifically designed for HRM applications. Our approach harnesses the integrate-and-fire time-encoding machine (IF-TEM) as a power-efficient, time-based, asynchronous sampler, generating a sequence of time instants without the need for a global clock. The ECG signal is represented as a linear combination of VPW-FRI pulses, which is then subjected to pre-filtering before being sampled by the IF-TEM sampler. A compactly supported robust filter with a frequency-domain alias cancellation condition is used to combat the effects of noise. Our reconstruction process involves consecutive partial summations of discrete representations of the input signal derived from the series of time encodings, further enhancing the accuracy of the reconstructed ECG signals. Additionally, we introduce an IF-TEM sampling hardware system for ECG signals, implemented using an analog filter device. The firing rate is 42-80Hz, equivalent to approximately 0.025-0.05 of the Nyquist rate. Our hardware validation bridges the gap between theory and practice and demonstrates the robust performance and practical applicability of our approach in accurately monitoring heart rates and reconstructing ECG signals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hila Naaman, Daniel Bilik, Shlomi Savariego, Moshe Namer, Yonina C. Eldar. 2024-05-22. ECG-TEM: Time-based sub-Nyquist sampling for ECG signal reconstruction and Hardware Prototype. https://arxiv.org/abs/2405.13904

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP