Charge Amplification in Low Pressure CF4:SF6:He Mixtures with a Multi-Mesh ThGEM for Directional Dark Matter Searches

Abstract

The CYGNO collaboration is developing next generation directional Dark Matter (DM) detection experiments, using gaseous Time Projection Chambers (TPCs), as a robust method for identifying Weakly Interacting Massive Particles (WIMPs) below the Neutrino Fog. SF6 is potentially ideal for this since it provides a high fluorine content, enhancing sensitivity to spin-dependent interactions and, as a Negative Ion Drift (NID) gas, reduces charge diffusion leading to improved positional resolution. CF4, although not a NID gas, has also been identified as a favourable gas target as it provides a scintillation signal which can be used for a complimentary light/charge readout approach. These gases can operate at low pressures to elongate Nuclear Recoil (NR) tracks and facilitate directional measurements. In principle, He could be added to low pressure SF6/CF4 without significant detriment to the length of 16S, 12C, and 19F recoils. This would improve the target mass, sensitivity to lower WIMP masses, and offer the possibility of atmospheric operation; potentially reducing the cost of a containment vessel. In this article, we present gas gain and energy resolution measurements, taken with a Multi-Mesh Thick Gaseous Electron Multiplier (MMThGEM), in low pressure SF6 and CF4:SF6 mixtures following the addition of He. We find that the CF4:SF6:He mixtures tested were able to produce gas gains on the order of 10^4 up to a total pressure of 100 Torr. These results demonstrate an order of magnitude improvement in charge amplification in NID gas mixtures with a He component.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F. D. Amaro, E. Baracchini, L. Benussi, S. Bianco, F. Borra, C. Capoccia, M. Caponero, D. S. Cardoso, G. Cavoto, I. A. Costa, T. Crane, E. Dane, M. DAstolfo, G. Dho, F. Di Giambattista, G. DImperio, E. Di Marco, J. M. F. Dos Santos, A. C. Ezeribe, D. Fiorina, F. Iacoangeli, H. P. Lima Junior, G. S. P. Lopes, G. Maccarrone, R. D. P. Mano, R. R. Marcelo Gregorio, D. J. G. Marques, G. Mazzitelli, A. G. McLean, C. M. B. Monteiro, R. A. Nobrega, I. F. Pains, E. Paoletti, L. Passamonti, S. Piacentini, D. Piccolo, D. Pierluigi, D. Pinci, A. Prajapati, F. Renga, R. J. d. C. Roque, F. Rosatelli, A. Russo, G. Saviano, A. Scarff, N. J. C. Spooner, R. Tesauro, S. Tomassini, S. Torelli. 2024-05-28. Charge Amplification in Low Pressure CF4:SF6:He Mixtures with a Multi-Mesh ThGEM for Directional Dark Matter Searches. https://arxiv.org/abs/2405.17967

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det