Model predictive control of residential air conditioning could reduce energy costs and greenhouse gas emissions while maintaining or improving occupants' thermal comfort. However, most approaches to predictive air conditioning control either do not model indoor humidity or treat it as constant. This simplification stems from challenges with modeling indoor humidity dynamics, particularly the high-order, nonlinear equations that govern heat and mass transfer between the air conditioner's evaporator coil and the indoor air. This paper develops a machine-learning approach to modeling indoor humidity dynamics that is suitable for real-world deployment at scale. This study then investigates the value of humidity modeling in four field tests of predictive control in an occupied house. The four field tests evaluate two different building models: One with constant humidity and one with time-varying humidity. Each modeling approach is tested in two different predictive controllers: One that focuses on reducing energy costs and one that focuses on constraining electric power below a utility-specified threshold. The two models lead to similar performance for reducing energy costs. Combining the results of this study and a prior heating study of the same house, the estimated year-round energy cost savings were $340-497 or 22-31% (95% confidence intervals); these savings were consistent across both humidity models. However, in the demand response tests, the simplifying assumption of constant humidity led to far more frequent and severe violations of the power constraint. These results suggest that accurate building models are important for nonlinear objectives, such as reducing or constraining peak demand, while for linear objectives such as reducing energy costs or emissions, model accuracy is less important.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elias N. Pergantis, Parveen Dhillon, Levi D. Reyes Premer, Alex H. Lee, Davide Ziviani, Kevin J. Kircher. 2024-09-15. Humidity-Aware Model Predictive Control for Residential Air Conditioning: A Field Study. https://arxiv.org/abs/2407.01707

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Safe learning-based control via function-based uncertainty quantification

Uncertainty quantification is essential when deploying learning-based control methods in safety-critical systems. This is commonly realized by constructing uncertainty tubes that enclose the unknown function of interest, e.g., the reward and constraint functions or the underlying dynamics model, with high probability. However, existing approaches for uncertainty quantification typically rely on restrictive assumptions that encode smoothness properties of the unknown function, such as a known norm in a function space. Moreover, these methods usually struggle with discontinuities. In this paper, we model the unknown function as a random function from which independent and identically distributed realizations can be generated. We then construct uncertainty tubes via the scenario approach that hold with high probability. Our uncertainty tubes rely solely on sampled realizations and can therefore accommodate discontinuities represented by the sampling model. We integrate these uncertainty tubes into a safe Bayesian optimization algorithm with which we safely tune control parameters on a real Furuta pendulum.

eess.SY

Enhanced ShockBurst for Ultra Low-Power On-Demand Sensing

On-demand sensing requires battery-powered Internet-of-Things (IoT) and implantable medical devices to remain in deep sleep and activate wireless communication only when data transmission is required. In such systems, battery lifetime depends strongly on radio active time. This work investigates how communication architecture and physical layer (PHY) configuration influence radio active time by comparing connection-oriented Bluetooth Low Energy (BLE) with connectionless Enhanced ShockBurst (ESB) on identical BLE-compatible hardware. Under identical 2 Mbps PHY configurations, ESB reduces wake-up latency and energy consumption to approximately one-twentieth of BLE by eliminating connection establishment and maintenance overhead. Increasing the ESB PHY rate from 2 to 4 Mbps further shortens packet airtime by approximately 52% and reduces transmission energy by approximately 43%. Finally, a first-in, first-out (FIFO)-triggered implantable loop recorder prototype demonstrates that jointly optimizing communication architecture, PHY configuration, and buffered transmission enables sleep-wake operation and reduces total system power consumption by approximately 60% compared with conventional BLE operation. These results identify minimizing radio active time as a key design principle for ultra-low-power on-demand sensing and provide practical guidance for battery-powered sensing systems.

eess.SY

Receding Horizon Multi-Agent Deceptive Path Planner

Deceptive path planning enables autonomous agents to obscure their true goals from observers by deviating from an expected optimal path. Prior work largely solves full-horizon, end-to-end optimization for single agents, which is expensive to recompute online and difficult to scale or adapt en route. We propose a unified framework for deceptive path planning using a Boltzmann distribution, computing over short-horizon candidate trajectories within a receding-horizon loop. By param- By iterating a user-defined cost that captures deception, resources, and smoothness, and optionally includes coupling terms between agents, the framework yields stochastic policies that balance the tradeoff between optimal paths and deceptive deviation. Policies are updated locally and do not require training. The level of deception and adherence to constraints can be dynamically tuned, enabling online adaptation to changes in goals and constraints such as obstacles. This step-by-step tuning opens the door to new forms of dynamic deception. Simulation studies demonstrate the flexibility of our approach, maintaining deception while adapting to environmental and constraint updates, avoiding the recomputation required by full-horizon methods, and supporting intuitive tuning via a small set of parameters

eess.SY