Search arXivSearch

arXiv · 2407.08075

Temperature-Dependent Photoluminescence of PEDOT:PSS for use as Transparent Electrodes in the DarkSide-20k Time Projection Chamber

Abstract

Dual-phase time-projection chambers (TPCs) filled with noble elements are used for particle detection, with many focusing on rare-event searches. These detectors measure two signals: one from scintillation light, and another from drifting ionized electrons. The DarkSide-20k design uses a transparent vessel with external photodetectors. Electrodes, used to drift the electrons, are located between the active medium and the photodetectors, requiring them to be transparent to allow scintillation light to transmit through them. The transparent electrode coating for DarkSide-20k is poly(3,4-ethylenedioxythiophene) poly(styrene sulfonate) (PEDOT:PSS) or Clevios. For rare-event search detectors, the fluorescence of materials that are between the active volume and the photodetectors may lead to backgrounds in the data. Since Clevios is a new material for TPC electrodes, its fluorescent properties need to be characterized to understand their potential impact on backgrounds. Previous studies have indicated that Clevios can fluoresce, with maximal fluorescence produced using UV-excitation. Our study analyzes the fluorescence of Clevios, under UV-excitation, using both time-resolved and spectral techniques between 4 K and 300 K. We find that the fluorescence of Clevios is negligible when compared to the fluorescence of common fluorescent materials used in TPCs, such as 1,1,4,4-tetraphenyl-1,3-butadiene (TPB).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nicholas Swidinsky, Emma Ellingwood, Jonathan Hucker, Peter Skensved, Philippe Di Stefano, Jeffery Mason, Mark Boulay, Ashlea Kemp, Frederick Schuckman, Yi Wang. 2024-07-10. Temperature-Dependent Photoluminescence of PEDOT:PSS for use as Transparent Electrodes in the DarkSide-20k Time Projection Chamber. https://arxiv.org/abs/2407.08075

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det