Search arXivSearch

arXiv · 2407.12658

FastSAM-3DSlicer: A 3D-Slicer Extension for 3D Volumetric Segment Anything Model with Uncertainty Quantification

Abstract

Accurate segmentation of anatomical structures and pathological regions in medical images is crucial for diagnosis, treatment planning, and disease monitoring. While the Segment Anything Model (SAM) and its variants have demonstrated impressive interactive segmentation capabilities on image types not seen during training without the need for domain adaptation or retraining, their practical application in volumetric 3D medical imaging workflows has been hindered by the lack of a user-friendly interface. To address this challenge, we introduce FastSAM-3DSlicer, a 3D Slicer extension that integrates both 2D and 3D SAM models, including SAM-Med2D, MedSAM, SAM-Med3D, and FastSAM-3D. Building on the well-established open-source 3D Slicer platform, our extension enables efficient, real-time segmentation of 3D volumetric medical images, with seamless interaction and visualization. By automating the handling of raw image data, user prompts, and segmented masks, FastSAM-3DSlicer provides a streamlined, user-friendly interface that can be easily incorporated into medical image analysis workflows. Performance evaluations reveal that the FastSAM-3DSlicer extension running FastSAM-3D achieves low inference times of only 1.09 seconds per volume on CPU and 0.73 seconds per volume on GPU, making it well-suited for real-time interactive segmentation. Moreover, we introduce an uncertainty quantification scheme that leverages the rapid inference capabilities of FastSAM-3D for practical implementation, further enhancing its reliability and applicability in medical settings. FastSAM-3DSlicer offers an interactive platform and user interface for 2D and 3D interactive volumetric medical image segmentation, offering a powerful combination of efficiency, precision, and ease of use with SAMs. The source code and a video demonstration are publicly available at https://github.com/arcadelab/FastSAM3D_slicer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yiqing Shen, Xinyuan Shao, Blanca Inigo Romillo, David Dreizin, Mathias Unberath. 2024-07-17. FastSAM-3DSlicer: A 3D-Slicer Extension for 3D Volumetric Segment Anything Model with Uncertainty Quantification. https://arxiv.org/abs/2407.12658

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV