Search arXivSearch

arXiv · 2408.00556

Mechanical design concept version 2.0 for the miniBeBe subsystem of the Multi-Purpose Detector at the Nuclotron-based Ion Collider fAcility of the Joint Institute for Nuclear Research

Abstract

We present the design of the mechanical structure of the mini Beam-Beam detector, a subsystem of the Multi-Purpose Detector, soon to enter into operation at the Nuclotron based Ion Collider fAcility of the Joint Institute for Nuclear Research. The miniBeBe detector was designed and is currently being developed by the Mexican team of the NICA Collaboration to contribute to the level-zero trigger of the Time of Flight Detector. The mechanical structure meets the requirements of minimizing the material budget and be free of ferromagnetic materials, without compromising its robustness. The design also allows for easy module replacement for maintenance and overall removal at the end of the first stage of the experiment, without affecting the rest of the subsystems, to leave room for the installation of the Inner Tracking System. In addition, a Finite Element Method analysis of the mechanical components under load was performed. Based on this analysis, it was determined that the design meets the space constraints within the Multi-Purpose Detector, as well as a deformation of less than 1 mm with overall stress of less than 2 MPa, such that no material used in the design is at risk of mechanical failure during operation. The heat transfer analysis of the cooling system revealed that the temperature of the cooling plate is maintained within a range of $19.00^{\circ}$C to $21.41^{\circ}$C, which is sufficient to ensure that the silicon photomultipliers operate below a temperature of 25.00$^{\circ}$C, thereby optimizing their functionality

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Herrera, M. E. Patiño, Mauricio Alvarado, Ivonne Maldonado, Denis Andreev, Alejandro Ayala, Wolfgang Bietenholz, César Ceballos, Eleazar Cuáutle, Isabel Domínguez, L. A. Hernández, Israel Luna, Tuyana Lygdenova, Pablo Martínez-Torres, Alfredo Raya, Ulises Sáenz-Trujillo, M. E. Tejeda-Yeomans, Galileo Tinoco-Santillán. 2025-02-20. Mechanical design concept version 2.0 for the miniBeBe subsystem of the Multi-Purpose Detector at the Nuclotron-based Ion Collider fAcility of the Joint Institute for Nuclear Research. https://arxiv.org/abs/2408.00556

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det