Analysis of critical points of the In-Vessel Retention safety evaluation

Abstract

In-Vessel Retention (IVR) strategy for nuclear reactors in case of a Severe Accident (SA) intends to stabilize and retain the corium in the vessel by using the vessel wall as a heat exchanger with an external water loop. This strategy relies on simple actions to be passively taken as soon as SA signal is raised: vessel depressurization and reactor pit flooding. Then, the strategy is successful if the vessel keeps it integrity, which means that the heat flux coming from the corium pool does not exceed the cooling capacity of the External Reactor Vessel Cooling (ERVC) at each location along the vessel wall (no vessel melt-through) and the ablated vessel wall is mechanically resistant. The main uncertainties in this IVR safety evaluation are associated to the thermal load applied from the corium pool to the vessel wall and the resulting minimum vessel thickness after ablation. Indeed, the heat fluxes distribution along the vessel wall is directly dependent on the corium stratification which occurs as aresult of thermochemical interactions in the pool: when liquid steel is mixed with UO2 and partially oxidized Zr coming from the degradation of the fuel and claddings, there is a phase separation between oxide and metal phases due to a gap of miscibility. The primordial impact of the corium behaviour in the lower plenum of the reactor vessel on the IVR safety evaluation was clearly highlighted in the Phenomena Identification Ranking Table (PIRT) on IVR performed in the frame of the European IVMR (In-Vessel Melt Retention) project (Fichot et al., 2019). As a result, the focus is made in this paper on the critical points which impact the value of the minimum vessel thickness orequivalently the maximum heat flux reached at the outer surface of the vessel wall. Efficiency of the ERVC and mechanical resistance of the vessel wall are consequently not discussed here.The main objective is to identify the generic critical situations leading to an excessive heat flux to the vessel wall and the investigation of possible means to avoid them. In this perspective, the calculations of IVR strategy done by the project partners for different reactor designs and accident scenarios were used as a database to identify and understand the occurrence of critical configurations with excessive heat flux to the vessel wall. The results of 25 sequences are used, which correspond to 9 different reactor designs: a generic PWR 900MWe, a PWR 1100MWe with heavy reflector, a generic PWR 1300MWe, a generic Konvoi 1300MWe, a generic German BWR69, aNordic BWR, a BWR-5 Mark II, a VVER1000 and a VVER440/v213. In addition, different SA integral codes (ASTEC, ATHLET-CD, MAAP -combined with MAAP_EDF and PROCOR codes for simulation of lower plenum behavior-, MELCOR and RELAP/SCDAPSIM codes) are used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laure Carénini, Florian Fichot. 2024-08-26. Analysis of critical points of the In-Vessel Retention safety evaluation. https://arxiv.org/abs/2408.15290

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det