Chandra Surface Thermophysical Experiment (ChaSTE) is one of the payloads flown onboard the Chandrayaan-3 lander. The objective of the experiment is in-situ investigation of thermal behaviour of outermost 100 mm layer of the lunar surface by deploying a thermal probe. The probe consists of 10 temperature sensors (Platinum RTDs) mounted at different locations along the length of the probe to measure lunar soil temperatures as a function of depth. A heater is also mounted on the probe for thermal conductivity measurements. The onboard electronics of ChaSTE has two parts, Front-End Electronics (FEE) and processing electronics (PE). The front-end electronics (FEE) card is responsible for carrying out necessary sensor signal conditioning,which includes exciting the RTD sensors,acquiring analog voltages and then converting the acquired analog signals to digital signals using an Analog to Digital Converter(ADC). The front-end card is further interfaced with the processing electronics card for digital processing and spacecraft interface.The calibration, characterisation and functional test activities of Front-End Electronics of ChaSTE were carried out with the objective of testing and ensuring proper functionality and performance.A two phase calibration process involving electronic offset correction and temperature calibration were carried out. All these activities were successfully completed and the results from them provided us with a really good understanding of the behaviour of the FEE under different thermal and electrical conditions as well as when subjected to the simulated conditions of the actual ChaSTE experiment. The performance of the ChaSTE front-end electronics was very much within the design margins and its behaviour in simulated lunar environment was as desired. The data from these activities is useful in the interpretation of the actual science data of ChaSTE.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K. Durga Prasad, Chandan Kumar, Sanjeev K. Mishra, P. Kalyana S. Reddy, Janmejay Kumar, Tinkal Ladiya, Arpit Patel, Anil Bhardwaj. 2024-08-30. Characterisation of Front-End Electronics of ChaSTE experiment onboard Chandayaan-3 lander. https://arxiv.org/abs/2409.00150

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det