Search arXivSearch

arXiv · 2409.02815

Development of the Multichannel Pulsed Ultrasonic Doppler Velocimeter for the measurement of liquid metal flow

Abstract

In the present study, by adopting the advantage of ultrasonic techniques, we developed a Multichannel Pulsed Ultrasonic Doppler Velocimetry (MPUDV) to measure the 2D2C velocity fields of liquid metal flow. Due to the specially designed Ultrasonic host and post-processing scheme, the MPUDV system can reach a high spatiotemporal resolution of 50 Hz and 3 mm. The flow loop contains a cavity test section to ensure a classical recirculating flow was built to validate the accuracy of MPUDV in velocity field measurement. In the initial phase of the study, water with tracer particles was selected as the working liquid to ensure the velocity field measurements by the well-developed Particle Image Velocimetry (PIV). A comparison of the data obtained from the PIV and MPUDV methods revealed less than 3 differences in the 2D2C velocity field between the two techniques during simultaneous measurements of the same flow field. This finding strongly demonstrates the reliability of the MPUDV method developed in this paper. Moreover, the ternary alloy GaInSn was selected as the working liquid in the flow loop to validate the efficacy of the MPUDV in measuring 2D-2C velocity fields. A series of tests were conducted in the cavity at varying Reynolds numbers, ranging from 9103 to 24123. The measurements demonstrated that the MPUDV could accurately measure the flow structures characterized by a central primary circulation eddy and two secondary eddies in the opaque liquid metal. Furthermore, it was found that the vortex center of the primary circulating eddy and the size of the secondary eddies undergo significant alterations with varying Reynolds numbers, indicating the influence of inertial force on the flow characteristics in the recirculating flow. It is therefore demonstrated that the current MPUDV methodology is applicable for measuring a 2D2C velocity field in opaque liquid metal flows.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ding-Yi Pan, Yi-Fei Huang, Ze Lyu, Juan-Cheng Yang, Ming-Jiu Ni. 2024-09-04. Development of the Multichannel Pulsed Ultrasonic Doppler Velocimeter for the measurement of liquid metal flow. https://arxiv.org/abs/2409.02815

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mathematical modeling on peristaltic flow of a Prandtl fluid with effects of slip conditions and inclined magnetic field

The manuscript provides a description of a theoretical analysis of a non-Newtonian Prandtl fluid subject to peristaltic flow through an inclined asymmetric channel. We explore the effect of an inclined magnetic field on the peristaltic flow. This is relevant for applications involving fluid flow in narrow, inclined (tilted) tubes similar to blood vessels or the digestive system. The model also includes thermodynamic aspects such as heat diffusion (the Soret effect) and viscous dissipation resulting from wall-fluid slip conditions, which may help optimize medical devices such as lab-on-a-chip systems and dialysis machines. In this study, the concentration of a generic chemical, temperature, and fluid velocity are taken into account through mass, heat, and momentum balances, respectively. The solution is approximated using numerical techniques suitable for long wavelengths (low frequency) and low Reynolds numbers. The study also discusses trapping phenomena, which are crucial from a clinical point of view. The developed insights can improve the understanding of physiological flows in the gastrointestinal tract and blood vessels. By understanding how the fluid moves and how particles are trapped, these insights may contribute to the design of improved medical pumps and artificial organs. Graphical visualizations are provided for the fluid velocity profile, temperature distribution, and concentration of a generic chemical. Furthermore, the numerical results are validated through comparison with a closed-form solution from a benchmark problem.

physics.flu-dyn

Discovery of a dispersion model at high Peclet numbers

Peclet number characterises the transition from classical Taylor-Aris dispersion to convection-dominated longitudinal solute transport, with the classical model becoming inadequate at extremely high radial Peclet number $Pe_r$. We develop a novel explicit-closure one-dimensional (1-D) effective dispersion model for this high-$Pe_r$ regime by introducing two closure coefficients, $θ_u$ and $θ_d$, whose functional structures are identified using low-frequency transfer-function matching and a modified Kolmogorov-Arnold network (KAN). The resulting model captures the transition from classical Taylor-Aris dispersion at low $Pe_r$ to convection-dominated dispersion at high $Pe_r$. Analysis reveals that, in the high-$Pe_r$ regime, axial transport is redistributed between the effective convection flux and the dispersive flux, resulting in a reduced macroscopic convection velocity. Numerical validation demonstrates close agreement with the convection-diffusion model over the investigated high-$Pe_r$ conditions, while the classical Taylor-Aris model exhibits substantial deviations. Application of the proposed model to averaged flow velocity inversion further demonstrates improved velocity estimation, particularly in the high-$Pe_r$ regime. These results highlight the importance of accounting for non-classical dispersion for reliable contrast-agent-based arterial blood flow velocimetry and provide new insight into high-$Pe_r$ mass transport.

physics.flu-dyn

Optimization of fluid mixing by reinforcement learning using limit cycles of a dynamical system

We propose a method to overcome the difficulties encountered when applying reinforcement learning to fluid mixing processes. The proposed method has two main features: (i) it does not require detailed measurements of the flow state, and (ii) by effectively exploiting a stable limit cycle of a two-dimensional dynamical system (the Li'enard system), it can stably perform optimization without imposing explicit constraints on the control parameters. As an illustrative example, we optimize a process in which a fluid contained in a cylindrical vessel is mixed by periodically rotating the vessel. The resulting optimal vessel motion is physically reasonable: it reverses its direction of rotation before a solid-body rotation state is established. Furthermore, even when the fluid viscosity increases with time during the mixing process, the method can continuously adapt the control parameters to the changing viscosity.

physics.flu-dyn