Search arXivSearch

arXiv · 2409.15037

Tunable membrane-less dielectrophoretic microfiltration by crossing interdigitated electrodes

Abstract

Separation is a crucial step in the analysis of living microparticles. In particular, the selective microseparation of phytoplankton by size and shape remains an open problem, even though these criteria are essential for their gender and/or species identification. However, microseparation devices necessitate physical membranes which complicate their fabrication, reduce the sample flow rate and can cause unwanted particle clogging. Recent advances in microfabrication such as High Precision Capillary Printing allow to rapidly build electrode patterns over wide areas. In this study, we introduce a new concept of membrane-less dielectrophoretic (DEP) microseparation suitable for large scale microfabrication processes. The proposed design involves two pairs of interdigitated electrodes at the top and the bottom of a microfluidic channel. We use finite-element calculations to analyse how the DEP force field throughout the channel, as well as the resulting trajectories of particles depend on the geometry of the system, on the physical properties of the particles and suspending medium and on the imposed voltage and flow rates. We numerically show that in the negative DEP regime, particles are focused in the channel mid-planes and that virtual pillars array leads either to their trapping at specific stagnation points, or to their focusing along specific lines, depending on their dielectrophoretic mobility. Simulations allow to understand how particles can be captured and to quantify the particle separation conditions by introducing a critical dielectrophoretic mobility. We further illustrate the principle of membrane-less dielectrophoretic microseparation using the proposed setup, by considering the separation of a binary mixture of polystyrene particles with different diameters, and validate it experimentally.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nicolas Ruyssen, Bastien Oliva, Lylian Challier, Vincent Noël, Benjamin Rotenberg. 2025-04-08. Tunable membrane-less dielectrophoretic microfiltration by crossing interdigitated electrodes. https://doi.org/10.1088/1361-6463%2Fadc60d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Measuring vacancy-type defect density in monolayer semiconductors

Two-dimensional (2D) materials have attracted wide-spread interest due to their unique and tunable properties. Their optoelectronic, mechanical, and thermal properties are greatly influenced by crystal defects, which are, in turn, used to control these properties. However, experimental quantification of the density of defects, whether deliberately introduced or inherent, is very difficult in these atomically thin materials. Here we show that helium atom micro-diffraction can be used to measure the defect density in ~15x20um monolayer MoS2, a prototypical 2D semiconductor, quickly and easily compared to standard methods. We present a simple analytic model, the lattice gas equation, that captures the relationship between atomic Bragg diffraction intensity and defect density. The model, combined with ab initio scattering calculations, shows that our technique can immediately be applied to a wide range of 2D materials, independent of sample chemistry or structure. Additionally, wafer-scale characterization is immediately possible.

physics.app-ph

Compact Modeling of Oxide-Semiconductor, 2D Material, Carbon Nanotube, and Cryogenic Transistors with Experiment Verification

This paper presents a unified compact model for emerging transistor technologies, including oxide-semiconductor field-effect transistors (OSFETs), 2D material FETs (2DFETs), carbon nanotube FETs (CNFETs), and cryogenic MOSFETs. A unified charge-density formulation is developed to account for quantum confinement, trap charges, and band-tail states in channel charge calculations. A physics-based transport model is introduced to seamlessly capture carrier transport from the long-channel diffusive regime to the short-channel ballistic limit. Scaling models are incorporated to accurately describe 2D electrostatic effects. Cryogenic operation is modeled through the inclusion of band-tail states and temperature-dependent mobility and threshold voltage. The proposed model is validated against experimental data from the fabricated OSFETs with multiple channel lengths and published measurements of 2DFETs, CNFETs, and cryogenic MOSFETs. Excellent agreement is demonstrated across diverse device architectures, operating conditions, and material systems.

physics.app-ph

Multiplexing approaches to thermoradiative signatureless communications

Using mid-infrared emission from semiconductor devices for covert communications remains a relatively unexplored and yet promising opportunity. The phenomenon of negative luminescence allows for a method of signatureless covert communications where the net infrared emission of an emitting optoelectronic device is balanced to be identical to the ambient thermal background. In this work we provide a practical demonstration of covert data transfer over a thermoradiative channel with data rates up to 100 kbps. In addition, we demonstrate several additional multiplexing techniques that make the proposed thermoradiative communications method more secure against interception by achieving zero instantaneous optical emission, while remaining detectable if a sufficiently spatially or spectrally discerning observation is utilised. Finally, we discuss various application scenarios in which the proposed methods can be used to achieve secure signatureless communications.

physics.app-ph