Search arXivSearch

arXiv · 2409.20214

Nuclear fuel imaging using position-sensitive detectors

Abstract

We are evaluating the performance of a Passive Gamma Emission Tomography (PGET) device equipped with 3D position-sensitive cadmium zinc telluride (CZT) gamma-ray detectors when used for inspecting spent nuclear fuel assemblies (SFAs). Recent advancements in imaging detector technology may offer a method to extend the capabilities of such devices beyond standard safeguards applications, allowing an efficient non-invasive way to accurately characterise the properties of nuclear fuel assemblies. The efficiency of the currently used small CZT detectors is restricted by the limited likelihood of full gamma-ray absorption, which is needed for optimal imaging information. Employing larger CZT detectors would increase the probability of capturing the full energy of gamma rays, thereby enhancing the sensitivity of the PGET device and the quality of the reconstructed images. Large CZT detectors need to be position-sensitive to determine through which collimator slit a gamma ray travelled. Position sensitivity results from the pixelated readout of the CZT crystals. Pixelation potentially increases the spatial resolution of the system, which is currently determined by the collimator used. Pixelation allows resolving the position of arrival up to (readout pitch)/$\sqrt{12}$. We are additionally exploring the potential of utilising Compton imaging to provide information on the origin of gamma rays along the SFA. A simulation is created using Geant4 to compare the full photon absorption efficiency of large and current, small, crystals. Gamma rays of energy 661.7 keV and 1274 keV are targeted to the model describing the approved apparatus now equipped with 22 mm x 22 mm x 10 mm crystals of CZT. It is observed that the efficiency for photon absorption in this case is greatly increased when compared to the existing detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Santeri Saariokari, Peter Dendooven, Mounia Laassiri, Erik Brücken. 2025-01-08. Nuclear fuel imaging using position-sensitive detectors. https://arxiv.org/abs/2409.20214

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det