Search arXivSearch

arXiv · 2410.00549

Radiation Measurements Using Timepix3 with Silicon Sensor and Bare Chip in Proton Beams for FLASH Radiotherapy

Abstract

This study investigates the response of Timepix3 semiconductor pixel detectors in proton beams of varying intensities, with a focus on FLASH proton therapy. Using the Timepix3 ASIC chip, we measured the spatial and spectral characteristics of 220 MeV proton beams delivered in short pulses. The experimental setup involved Minipix readout electronics integrated with a Timepix3 chipboard in a flexible architecture, and an Advapix Timepix3 with a silicon sensor. Measurements were carried out with Timepix3 detectors equipped with GaAs and silicon Si sensors. We also investigated the response of a bare Timepix3 ASIC chip (without a sensor). The detectors were placed within a waterproof holder attached to the IBA Blue water phantom, with additional measurements performed in air behind a 2 cm-thick solid phantom. The results demonstrated the capability of the Timepix3 detectors to measure time-over-threshold (ToT) and count rate (number of events) in both conventional and ultra-high-dose-rates proton beams. The bare ASIC chip configuration sustained up to a dose rate (DR) of 270 Gy/s, although it exhibited limited spatial resolution due to low detection efficiency. In contrast, Minipix Timepix3 with experimental GaAs sensors showed saturation at low DR=5 Gy/s. Furthermore, the Advapix Timepix3 detector was used in standard and customized configurations. In the standard configuration (Ikrum =5), the detector showed saturation at DR=5 Gy/s. But, in the customized configuration when the per-pixel discharging signal (Ikrum) was increased to 80, the detector demonstrated enhanced performance by reducing the duration of the ToT signal, allowing beam spot imaging up to DR=28 Gy/s in the plateau region of the Bragg curve. For such DR, the frame acquisition time was reduced to the order of microseconds, meaning only a fraction of the pulse (with pulse lengths on the order of milliseconds) was captured.

Explore related subjects

Keep this discovery

BibTeXRIS

C. Oancea, J. Šolc, C. Granja, E. Bodenstein, F. Horst, J. Pawelke, J. Jakubek. 2024-10-01. Radiation Measurements Using Timepix3 with Silicon Sensor and Bare Chip in Proton Beams for FLASH Radiotherapy. https://arxiv.org/abs/2410.00549

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det