Geometric Uncertainty of Patient-Specific Blood Vessels and its Impact on Aortic Hemodynamics

Abstract

In the context of numerical simulations of the vascular system, local geometric uncertainties have not yet been examined in sufficient detail due to model complexity and the associated large numerical effort. Such uncertainties are related to geometric modeling errors resulting from computed tomography imaging, segmentation and meshing. This work presents a methodology to systematically induce local modifications and perform a sufficient number of blood flow simulations to draw statistically relevant conclusions on the most commonly employed quantities of interest, such as flow rates or wall shear stress. The surface of a structured hexahedral mesh of a patient-specific aorta is perturbed by displacement maps defined via Gaussian random fields to stochastically model the local uncertainty of the boundary. Three different cases are studied, with the mean perturbation magnitude of $0.25$, $0.5$ and $1.0~$mm. Valid, locally perturbed meshes are constructed via an elasticity operator that extends surface perturbations into the interior. Otherwise, identical incompressible flow problems are solved on these meshes, taking physiological boundary conditions and Carreau fluid parameters into account. Roughly $300\,000$ three-dimensional non-stationary blood flow simulations are performed for the three different perturbation cases to estimate the probability distributions of the quantities of interest. Convergence studies justify the spatial resolution of the employed meshes. Overall, the results suggest that moderate geometric perturbations result in reasonable engineering accuracy (relative errors in single-digit percentage range) of the quantities of interest, with higher sensitivity for gradient-related measures, noting that the observed errors are not negligible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Domagoj Bošnjak, Richard Schussnig, Sascha Ranftl, Gerhard A. Holzapfel, Thomas-Peter Fries. 2024-10-25. Geometric Uncertainty of Patient-Specific Blood Vessels and its Impact on Aortic Hemodynamics. https://doi.org/10.1016/j.compbiomed.2025.110017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph