arXiv · 2411.03476
Functional Verification for Endcap Concentrator ASICs in the High-Granularity Calorimeter Upgrade of CMS
Abstract
The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D) streams from the HGCROC to the lpGBT. The ECONs will operate in a radiation environment with a High-Energy Hadron (${E\geq20MeV}$) flux up to $2\cdot10^{7} cm^{-2}s^{-1}$. This contribution describes the Universal Verification Methodology (UVM)-based functional verification of the ECON ASICs focusing on the re-use of existing components to manage the complexity of the verification environment.
Explore related subjects
Keep this discovery
M. Lupi, G. Bergamin, D. Ceresa, D. Coko, G. Cummings, V. Gingu, M. Hammer, J. Hirschauer, J. Hoff, N. Kharwadkar, S. Kulis, C. Mantilla-Suarez, D. Noonan, P. Rubinov, S. Scarfì, A. Shenai, C. Syal, X. Wang, R. Wickwire, J. Wilson. 2024-11-05. Functional Verification for Endcap Concentrator ASICs in the High-Granularity Calorimeter Upgrade of CMS. https://doi.org/10.1088/1748-0221/20/02/c02004
Cite the original work for its findings. Save a collection to share your selection of sources.