Search arXivSearch

arXiv · 2411.05824

Navigating Distribution Shifts in Medical Image Analysis: A Survey

Abstract

Medical Image Analysis (MedIA) has become indispensable in modern healthcare, enhancing clinical diagnostics and personalized treatment. Despite the remarkable advancements supported by deep learning (DL) technologies, their practical deployment faces challenges posed by distribution shifts, where models trained on specific datasets underperform on others from varying hospitals, or patient populations. To address this issue, researchers have been actively developing strategies to increase the adaptability of DL models, enabling their effective use in unfamiliar environments. This paper systematically reviews approaches that apply DL techniques to MedIA systems affected by distribution shifts. Rather than organizing existing methods by technical characteristics, we explicitly bridge real-world clinical constraints -- such as limited data accessibility, strict privacy requirements, and heterogeneous collaboration protocols -- with the technical paradigms able to address them. By establishing this connection between operational constraints and methodological evolution, we categorize existing works into Joint Training, Federated Learning, Fine-tuning, and Domain Generalization, each aligned with specific healthcare scenarios. Beyond this taxonomy, our empirical analysis suggests that, as domain information becomes progressively less accessible across these paradigms, performance improvements become increasingly constrained, and further uncovers a gradual shift in methodological focus from explicit distribution alignment toward uncertainty-aware modeling, ultimately pointing to the need for more deployability-aware design in real-world MedIA.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zixian Su, Jingwei Guo, Xi Yang, Qiufeng Wang, Frans Coenen, Amir Hussain, Kaizhu Huang. 2026-06-13. Navigating Distribution Shifts in Medical Image Analysis: A Survey. https://arxiv.org/abs/2411.05824

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV