Search arXivSearch

arXiv · 2411.06598

Design and Characterization of a Novel Scintillator Array for In Vivo Monitoring During UHDR PBS Proton Therapy

Abstract

Background: Ultra-high dose rate proton therapy shows promise in tissue sparing by enhancing therapeutic ratio through the FLASH effect. In radiotherapy, accurate in vivo dosimetry is crucial for quality assurance, but remains challenging for UHDR as existing systems lack spatial and temporal resolution to verify dose and dose rate in complex anatomical regions, especially for PBS proton therapy. Purpose: To develop and evaluate a novel 3D surface dosimetry method for UHDR PBS proton therapy using high-speed imaging of a scintillator array for real-time, high-resolution surface dose monitoring. The spatial, temporal, and dosimetric components are validated via imaging of a QA phantom and comparison against TPS predictions. Methods: A deformable multi-element scintillator array was designed with 7.5mm element pitch and 0.5mm inter-element gap. Scintillation linearity with dose was evaluated with variation in response to increasing imaging and irradiation angles. WED testing evaluated beam attenuation at two energy levels. Scintillation emission was imaged at 1kHz and mesh position was monitored via 2-camera stereovision. System setup was validated using a 3D QA phantom to assess spatial accuracy and guide setup correction. Stereovision properties of array elements guided angular correction and geometric transformation. Kernel-based residual spot fitting derived cumulative dose maps compared to TPS dose profile of 5x5cm UHDR PBS delivery using 3%/2mm gamma analysis. PBS and maximum dose rate maps were calculated. Results: Setup achieved average localization error of 0.62 mm, surpassing typical 1+ mm clinical threshold. Intensity correction based on angular information yielded cumulative spot dose uncertainty of ~1% (5.428mGy). Processed dose map compared to TPS via gamma analysis showed 99.9% passing rate at 3%/2mm. WED of the array measured 1.1mm, minimizing impact on dose distribution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roman Vasyltsiv, Joseph Harms, Megan Clark, David J. Gladstone, Brian W. Pogue, Rongxiao Zhang, Petr Bruza. 2024-11-10. Design and Characterization of a Novel Scintillator Array for In Vivo Monitoring During UHDR PBS Proton Therapy. https://arxiv.org/abs/2411.06598

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph