Search arXivSearch

arXiv · 2411.10306

Demonstration of the minimal coupling of horizontal accelerations to rotations in a torsion balance suspended from three wires

Abstract

The Cavendish torsion balance is the instrument of choice for measuring weak forces, such as gravity. Although torsion balances have extremely high sensitivity for measuring forces over ranges of a few cm and more, their dynamics make it difficult to extend this range to much less than fractions of mm. In particular forces such as the Casimir force are usually studied using atomic force microscopes. We present results of our studies of a simple torsion balance with a 3-wire suspension. This device should be able to maintain parallelism between flat plates of areas of a few $\sim\mathrm{cm^2}$ at separations of much less of 10's of $\mathrm{μm}$. In this paper we describe our experimental investigation into the coupling of ground tilt to the torsional rotation of the novel device. We show that, like the Cavendish torsion balance, the 3-wire torsion balance is highly insensitive to tilts. We also demonstrate that this tilt sensitivity is itself insensitive to shifts in the centre of mass position of the suspended mass. We discuss simple models of the 3-wire torsion balance that show that it is only the static wire lengths that determine the coupling of tilts and horizontal accelerations. We also discuss designs of torsion balances where sensitivity and noise rejection to tilts are optimised.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Amit Singh Ubhi, Clive C. Speake, Emilia Chick, Conner Gettings. 2024-11-20. Demonstration of the minimal coupling of horizontal accelerations to rotations in a torsion balance suspended from three wires. https://doi.org/10.1063/5.0249973

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det