Search arXivSearch

arXiv · 2411.12705

High-Efficiency and Low-Noise Detectors for the Upgraded CLASS 90 GHz Focal Plane

Abstract

We present the in-lab and on-sky performance for the upgraded 90 GHz focal plane of the Cosmology Large Angular Scale Surveyor (CLASS), which had four of its seven detector wafers updated during the austral winter of 2022. The update aimed to improve the transition-edge-sensor (TES) stability and bias range and to realize the high optical efficiency of the sensor design. Modifications included revised circuit terminations, electrical contact between the TES superconductor and the normal metal providing the bulk of the bolometer's heat capacity, and additional filtering on the TES bias lines. The upgrade was successful: 94% of detectors are stable down to 15% of the normal resistance, providing a wide overlapping range of bias voltages for all TESs on a wafer. The median telescope efficiency improved from $0.42^{+0.15}_{-0.22}$ to $0.60^{+0.10}_{-0.32}$ (68% quantiles). For the four upgraded wafers alone, median telescope efficiency increased to $0.65^{+0.06}_{-0.06}$. Given our efficiency estimate for the receiver optics, this telescope efficiency implies a detector efficiency exceeding $0.90$. The overall noise-equivalent temperature of the 90 GHz focal plane improved from 19 $μ$K$\sqrt{s}$ to 9.7 $μ$K$\sqrt{s}$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Carolina Núñez, John W. Appel, Rahul Datta, Charles L. Bennett, Michael K. Brewer, Sarah Marie Bruno, Ricardo Bustos, David T. Chuss, Nick Costen, Jullianna Denes Couto, Sumit Dahal, Kevin L. Denis, Joseph R. Eimer, Thomas Essinger-Hileman, Jeffrey Iuliano, Yunyang Li, Tobias A. Marriage, Jennette Mateo, Matthew A. Petroff, Rui Shi, Karwan Rostem, Deniz A. N. Valle, Duncan Watts, Edward J. Wollack, Lingzhen Zeng. 2025-07-29. High-Efficiency and Low-Noise Detectors for the Upgraded CLASS 90 GHz Focal Plane. https://doi.org/10.3847/1538-4365%2Fadc602

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM